SYSTEM CONFIGURATION GUIDE
–
NEC Express5800R120f-1M
NEC Corporation
Revision 6.0
– May 29, 2015
17
4.2.2 RAID 0/1 Controller with 1 GB Cache
Category
Product Name / Description
Part
Num
ber
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
LSI MegaRAID SAS 9362-8i
RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA
6Gb/s
N8103-176
Flash Backup
Recommended
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
N8103-181
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 2 sets
(Standard)
Drive Cage
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
(Standard)
NOTE:
Up to two Flash Backup Units can be installed in the system. Therefore, N8103-181 Flash backup
Unit cannot be installed for N8103-176, N8103-177 or N8103-178 when two N8103-179 RAID
controllers (including Flash Backup Unit as standard) are installed.
For Supported HDD/SSD, refer to
4.3.2
for Windows Server 2008/2008R2, Red Hat Enterprise Linux
6 or Red Hat Enterprise Linux 6(x86_64) with KVM feature.
Refet to
4.3.3
for Windows Server
2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature.
Refer to
4.3.4
for VMware.
All drives within a RAID array should be of the same type, capacity and rotation speed.
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs
and SATA SSDs can be mixed.
4.2.3 RAID 5/6 Controller with 1 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
N8103-177
Flash Backup
Recommended
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
N8103-181
Cable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 2 sets
(Standard)
Drive Cage
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
(Standard)
NOTE:
Up to two Flash Backup Units can be installed in the system. Therefore, N8103-181 Flash backup
Unit cannot be installed for N8103-176, N8103-177 or N8103-178 when two N8103-179 RAID
controllers (including Flash Backup Unit as standard) are installed.
For Supported HDD/SSD, refer to
4.3.2
for Windows Server 2008/2008R2, Red Hat Enterprise Linux
6 or Red Hat Enterprise Linux 6(x86_64) with KVM feature.
Refet to
4.3.3
for Windows Server
2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM feature.
Refer to
4.3.4
for VMware.
All drives within a RAID array should be of the same type, capacity and rotation speed.
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs
and SATA SSDs can be mixed.