Installing Electra Elite IPK II Optional Terminal Equipment
___________________________________________________________________________________
Document Revision 3
Electra Elite IPK II
To provide control to the recorder or to enable/disable the record
start warning tones, refer to
Table 9-2 AD(A)-R Unit Switch Settings
.
3.2.3
Installing the AD(A)-R Unit on a Multiline Terminal
The AD(A)-R Unit should be installed after the cables are connected
and the switches are set.
If wall mounting the Multiline Terminal, a WM-R Unit must be used.
Refer to
Section 13 Wall Mounting Multiline Terminals on page 8-29
.
1.
Unplug the telephone cord (and the AC-2R/AC-3R Unit cord if
installed) from the Multiline Terminal.
Table 9-2 AD(A)-R Unit Switch Settings
Switch
Description/Settings
SW1
SW1-1
Connects to Multiline Terminal
Connect = Default
SW1-2
Not Used
SW2
SW2-1
Sets External Equipment Impedance to 600
Ω
SW2-2
Used for Complex Impedance Devices
(< 30
Ω
Input Impedance)
Dip
Switche
s
(DSW)
DSW 1
Output Hook Signal to External Device
On = Output
Off = No Output (Default)
DSW 2
Record Confirmation Tone
On = Tone On
Off = Tone Off (Default)
DSW 3
and
DSW 4
Use T1/T2
On = Disable (Default)
Off = Enable
DSW 5
Reset Signal Upgrade
On = Normal (Default)
Off = Debugging
DSW
6~8
Firmware Upgrade
On = Firmware Upgrade
Off = Disable (Default)
Do not connect T1 and T2 when DSW switches 3 and 4 are On.
Содержание ELECTRA ELITE IPK II
Страница 2: ......
Страница 3: ...SYSTEM HARDWARE MANUAL INT 1076 IPK II DOCUMENT REVISION 3 VERSION 2000...
Страница 4: ......
Страница 6: ......
Страница 10: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 641: ...SYSTEM HARDWARE MANUAL NECUnified Solutions Inc Document Revision 3...
Страница 642: ......