background image

 

Default Features

Initial Startup Programming

 

1.

 

From any display telephone, press 

 

INTERCOM

 

 + Dial 

 

#*#* 

 

+ Enter the system pa 

 

HOLD.

2.

 

The system passwords are:

-

 

632379 (NECDSX)

 

 for Installer (level 3), 

 

9999

 

 for System Administrator 2 (level 2), 

 

0000

 

 for System 

Administrator 1 (level 1).

 

1.

 

In 

 

3101-01: Line Type

 

, assign the correct circuit type for each line. Analog line types are:

-

 

51

 

 for loop start DTMF, 

 

52

 

 for loop start DP.

 

1.

 

In 

 

2131-[01-64]: Line Access

 

, change each extension’s line access as required. The options are:

-

 

0

 

 for no access, 

 

1

 

 for incoming access only, 

 

2

 

 for outgoing access only, 

 

3

 

 for full access

 

2.

 

Using 

 

902x-Copy

 

 may save you time.

 

1.

 

In 

 

2132-[01-64]: Line Ringing

 

, set the ringing option for each extension, The options are:

-

 

0

 

 for lamp only (no ringing) day and night, 

 

1

 

 for day and night ringing, 

 

2

 

 for night ringing only, 

 

3

 

 for delay 

ringing day and night

 

2.

 

Using 

 

902x-Copy

 

 may save you time.

 

1.

 

Turn to the 

 

System Programming Password Protection

 

 feature to learn more about system passwords.

 

Default Features for Lines

1.

 

All lines are loop start DTMF.

Use 

 

3101-01: Line Type 

 

to change this assignment.

 

2.

 

Lines 1-12 ring on line keys 1-12 for extensions 300-315. (Lines 13-64 do not appear on line keys.)

All other extensions are lamp only for lines 1-12.

 

3.

 

To customize line ringing, use one of the following:

User Programmable Features code 

 

#RAL

 

. (See the 

 

User Programmable Features

 

 feature for more.)

Use 

 

2132-[01-64]: Line Ringing

 

.

 

Default Features for Extensions

1.

 

The circuit types for keyset extensions are automatically set when the extension is plugged in.

 

2.

 

Keyset users can place outside calls by:

Pressing a line key and dialing the outside number. (See the 

 

Central Of

fi

ce Calls, Placing

 

 feature for more.)

Pressing 

 

INTERCOM

 

, dialing 9, then dialing the outside number. (See the 

 

Line Group Routing

 

 feature for more.)

Line Dial-Up and Direct Line Access are disabled. (See the 

 

Central Of

fi

ce Calls, Placing

 

 feature for more.)

 

3.

 

All extensions have full incoming and outgoing access to all outside lines.

See 

 

Initial Startup Programming

 

 below to change this assignment.

 

4.

 

By default, Feature Keys 1-12 are line keys. Keys 13-24 are unde

fi

ned. See the 

 

Feature Keys

 

 feature for more.

 

Default Features for IntraMail

1.

 

Each extension has an IntraMail voice mailbox.

 

2.

 

All mailboxes are enabled. To disable a mailbox, see 

 

2141-01: Station Mailbox Type

 

.

 

3.

 

The IntraMail Automated Attendant does not answer outside calls. (See the 

 

Automated Attendant

 

 feature for more.)

 

1.

Enter the programming mode.

2.

Assign the correct circuit type to each of your installed lines.

3.

By default, each extension has full incoming and outgoing access to each line. To change this assignment:

4.

 

By default, extensions 300-315 ring immediately day and night for lines 1-12. To change this assignment:

 

5.

To change the default system passwords:

 

(1093088)

 

 

June 15, 2006, Rev 1
Printed in U.S.A.

 

Empowered by Innovation