4-8
1 2 3 4 5 6 7
A U TO
G A I N R E D
2 4 4
G A I N G R E E N
2 5 0
G A I N B L U E
2 2 0
O F F S E T R E D
9 0
O F F S E T G R E E N
8 5
O F F S E T B L U E
8 2
1 2 3 4 5 6 7
O S D D E S I G N
0
O S D S E L E C T
O S M
U R L
1
F I R S T A U TO
O N
T H R E S H O L D 4
6. Factory Mode Explanations
ON:
Accumulated time during the reception of input signals
(LED: green)
OFF:
Accumulated time in the power-saving mode and soft
power off mode (Only AC power input).
(LED: amber or off)
* The accumulated time (hours running) is reset when
FACTORY RESET is executed.
FACTORY PRESET:
All data are reset to the initial values.
AUTO:
Auto-adjustments for the gain and the offset.
GAIN R/G/B:
It is possible to adjust the gain values of
R, G, B, respectively.
* This value use Auto contrast of user menu.
OFFSET R/G/B:
It is possible to adjust the offset values of
R, G, B, respectively.
OSD DESIGN:
No Used.
OSD SELECT:
The OSD/OSM display is changed over for
the OSM menu.
OSM
(Setting for shipment)
OSD
URL:
Display or no display of URL (Internet address)
0:
Not displayed
1:
Displayed (WWW.NECMITSUBISHI.COM): Setting for
shipment (for North America and Europe version)
2:
Displayed (WWW.NMV.CO.JP): (for Japan)
FIRST AUTO:
Non touch auto adjust function switch.
ON:
NTAA function enable. (Setting for shipment)
OFF:
NTAA function disable.
THRESHOLD:
Image detect level of auto adjust.
0:
Min
16:
Max
4:
Initial
1 2 3 4 5 6 7
H O U R S R U N N I N G
O N 1 0 4 H
3 8 M
O F F 2 2 4 H 4 0 M
FA C TO RY R E S E T