OPERATING ACTIVITIES

 

The PLASMA IQ device does not have any user replaceable parts. It also has no user replaceable fuses. In case the 
device does not work, please follow the steps  below:

 

 

1

 

Connect the charger adapter to the wall  outlet.

 

2

 

Make sure that the charger LED lights up green. If the LED is not lit, check that the outlet to 

which the device is plugged in is getting sufficient power. If the LED is not lit, contact

 

Neauvia North America customer service at  1-866-836-3113.

 

3

 

Place the device in the charger. After a while, the LED should turn red. If the LED does not 

change color and the device does not work, please contact Neauvia North   America

 

customer service at 1-866-836-3113.

 

4

 

Wait until the device is fully charged before using. The LED on the charger will turn green 

when the device is fully  charged.

 

5

 

Remove the device from the charger. Press the H or L on the device. The LED on the device should light 

up indicating the device is ready to  use.

 

 

 

 

 

 

 

 

Warning: The product is intended for use with treatment electrodes, which are disposable products. 
After each treatment it is necessary to remove the electrode from the device. A new one should be 
used for each treatment.

 

 

 

Warning: HF surgical accessories should be selected in a way to avoid incompability and unsafe 
operation.

 

 

 

Warning: The PLASMA IQ device may only be used with Neauvia provided active   electrodes.

 

 

 

Warning: Operator should avoid HF output settings where maximum output voltage may exceed 
rated accessory voltage

 

 

 

Warning: Operator should regularly inspect the accessories. In particular, charger cables and HF 
energized devices should be checked for possible  damage.

 

 

 

Warning: When using the PLASMA IQ device, the rated voltage should comply with specifications in this 
manual.

 

Содержание PLASMA IQ

Страница 1: ...USER MANUAL Neauvia North America Customer Service 1 866 836 3113...

Страница 2: ...OPERATING CONDITIONS AND TRANSPORT 9 11 DISPOSAL OF EQUIPMENT 9 12 MEDICAL PRODUCT WARRANTY 9 13 CLEANING DISINFECTION MAINTENANCE 10 14 ELECTROMAGNETIC COMPATABILITY 11 15 OPERATING ACTIVITIES 12 16...

Страница 3: ...3 User Manual 1 KIT CONTENTS The basic set includes PLASMA IQ device The docking station ACM12US15 Charger Starter Kit 10 electrodes Manual on USB stick...

Страница 4: ...point on the patient s body resulting in temperature increase which in turn allows for controlled tissue destruction The microcurrent flow through the body can only take place at one selected point En...

Страница 5: ...tal conditions of use Temperature 50 77 F Pressure 980 1060 hPa Humidity 93 max Environmental conditions Storage Temperature 32 122 F Pressure 980 1060 hPa Humidity 10 90 Electrical Safety Class Class...

Страница 6: ...ype F AC Power Unit FRAGILE KEEP DRY F 32 F Handle with care keep dry Temperature storage and transport conditions Electrical Safety Class II 10 90 Humidity storage and transport conditions Caution Hi...

Страница 7: ...ed pacemaker Patients with metal or electrically conductive implants Cancer Eye region eye lids Pregnancy and breastfeeding Cardiac Disorders Cardiovascular Diseases Uncontrolled Diabetes Circulatory...

Страница 8: ...This may result in alternate site burns Use only all metal or all plastic trocar systems Warning Do not make any modifications to the device Warning Servicing must be performed only by persons authori...

Страница 9: ...ISPOSAL OF EQUIPMENT The product contains electronic parts It should be disposed of in accordance with applicable law The product contains lithium batteries you must follow the regulations regarding t...

Страница 10: ...l no longer visibly wet approximately 3 5 minutes Maintenance If you experience technical difficulty with your device contact Neauvia North America at 1 866 836 3113 email service neauvia us com PLASM...

Страница 11: ...gnetic fields with radio frequencies in accordance with PN EN 61000 4 3 2007 A1 2008 A2 2011 Range 80 2700 mHz 3V m Proximity field 385 450 710 745 780 810 870 930 1720 1845 1970 2450 5240 5500 5785 m...

Страница 12: ...er will turn green when the device is fully charged 5 Remove the device from the charger Press the H or L on the device The LED on the device should light up indicating the device is ready to use Warn...

Страница 13: ...ation ready not charging Docking station Red Charging of the battery in progress Warning Avoid using this device in close proximity to other devices or setting the device on or under another device be...

Страница 14: ...14 User Manual 17 DESCRIPTION OF WORKING MODES MAX POWER 5 W IMPEDANCE RATED 54 k FREQUENCY 40 kHz MODULATION FREQUENCY N A...

Страница 15: ...PTION OF WORKING MODES 17 1 Output power graph The following graphs shows dependency between device output power and load impedance The maximum output voltage levels for High Power the H 950 Vrms for...

Страница 16: ...cking station press the HIGH button and check that the yellow LED lights up 18 2 Preparing the device and equipment for work Before starting work with the device an active electrode should be inserted...

Страница 17: ...ds to be recharged Warning Do not leave the device uncharged or use the device before it is completely charged because it may damage or shorten the life of the battery inside the device Before chargin...

Страница 18: ...e in the docking station Warning The active electrode is a part that does not have electrical insulation therefore when installing or removing the active electrode avoid touching the buttons that acti...

Страница 19: ...esulting from improper maintenance inadequate power supply negligence or incompetence as well as faults or damage to parts subject to standard wear The warranty is void if the medical device has been...

Страница 20: ...NORTH AMERICA Neauvia North America Customer Service 1 866 836 3113 2019 Neauvia North America 8480 Honeycutt Road Raleigh NC 27615 neauvia com PI NAM 01 190001 REV 022020...

Отзывы: