NE41 09010-02 v3.0
D-SERVER
Technical Handbook
neat
53
5.4.1 System parameters
System parameter
Description
Default value
alarm-log-size-in-web
Parameter control the appearance of tables in the
D-SERVER web page.
Determines the number of alarms that the alarm
log lists.
20
bus-disconnect-timeout-sec
Parameter control how the D-SERVER communi-
cates with a D-TECT unit.
Determines for how long time a D-TECT unit can
stop responding before the D-SERVER considers
the unit as disconnected and stops polling it.
180
bus-query-new-interval-sec
Parameter control how the D-SERVER communi-
cates with a D-TECT unit.
Determines the time between checks for newly
connected D-TECT units.
60
bus-rx-timeout-ms
Parameter control how the D-SERVER communi-
cates on the serial bus.
Determines the length of silence on the serial bus
before sending a message.
300
bus-send-retries
Parameter control how the D-SERVER communi-
cates on the serial bus.
Determines the number of times that the D-SERVER
tries to send a message to a D-TECT unit if it does
not reply.
3
bus-tx-delay-ms
Parameter control how the D-SERVER communi-
cates on the serial bus.
Determines the length of silence on the serial bus
before sending a message.
5
cobs-allow-handle-same-user-
alarms
When a COBS device makes a presence or an alarm
done indication, this flag will control if all other
alarms from the same user should be set to pres-
ence/ready as well.
Supported in Application v1.18.62 and forward.
0
cobs-allow-presence-without-
action
Staff can select Presence from the C-3110 menu. No
need to do a traditional Presence. Presence option
is visible even if feature is disabled.
Supported in Application 1.18.61 and forward.
0
cobs-open-door-number
Which number on the COBS C-3110 that should be
treated as a door opening command.
1
cobs-presence-number
Which number on the COBS C-3110 that should be
treated as a presence indication.
Supported in Application v1.18.61 and forward.
3
cobs-talk-presence-timeout
Since we can only have one cobs-talk-presence
indication in the system at the same time, this pa-
rameter controls how long the cobs-talk-presence
indication remains in the system.
5
cobs-treat-presence-as-busy
If the system should treat COBS personnel that are
present the same way they are treated when they
are busy, i.e., low prio alarms will not be received.
If Alarm distribution Priority is set to High, person-
nel will receive Assistance alarms despite they are
busy.
Supported in Application v1.20.00 and forward.
0