17.LED INDICATOR
Here is the meaning of the LED indicator on the side of
the battery (Fig. 1 - Ref. C):
•
Green LED Steady:
battery is starting up. Voltage
on poles not present.
•
Green LED flashing:
battery active. Voltage on
poles present.
•
Blue LED flashing:
battery powering down with
Bluetooth active. Voltage on poles not present.
•
Purple LED flashing:
battery in shutdown with
Bluetooth not active. Voltage on poles not present.
•
Red LED flashing:
battery alarm. Voltage on poles
not present.
•
Orange LED Flashing:
Temperature range limit.
Voltage on poles present.
•
Orange LED Steady:
aggiornamento Firmware,
eseguito da App mobile, di un dispositivo N-BUS
collegato alla rete.
•
LED Off:
Battery inactive or Bluetooth active.
Voltage on poles not present.
18.ALARMS
The internal
BMS
(Battery Management System)
automatically manages all possible faults generated by
external or internal causes to the battery. The fault is
indicated by the red flashing of the indicator light (Fig. 1
- Ref. C) see chapter "LED indicator".
Possible faults are:
•
Cell Very low:
voltage of one or more cells below
the allowed limit.
•
Undervoltage:
battery below 10.5V±0.1V.
•
Very high charged battery:
one or more cells
above the allowed limit.
21