background image

20

Содержание POWERCHARGERPRO PFC0150-12CH10S

Страница 1: ...anual ITALIANO INGLESE Valido per i seguenti modelli Valid for the following models PFC0150 12CH10S PFC0300 12CH15S PFC0600 12CH20S PFC0600 12CH25S PFC0300 24CH10S PFC0600 24CH15S PFC0600 24CH20S PFC1200 24CH30S PFC1200 36CH25S ...

Страница 2: ...he European Directive 2012 19 EU Comply with local waste disposal regulations do not dispose of old products with normal household waste The proper disposal of products that can no longer be used prevents potential negative consequences for the environment and for the population ...

Страница 3: ...NDICATORE REMOTO PIN 2 10 9 INDICATORI LED 12 10 CARATTERISTICHE TECNICHE 13 11 F A Q 18 12 GARANZIA 19 1 SAFETY INSTRUCTIONS 21 2 CONTENTS OF THE PACK 22 3 DESCRIPTION 22 4 ARCHITECTURE 23 5 CHARGING CURVE SELECTION 24 6 CHARGING CURVES ANALISYS 26 7 INSTALLATION 28 8 REMOTE STATUS LED CONNECTION PIN 2 29 9 LED INDICATORS 31 10 TECHNICAL FEATURES 32 11 F A Q 36 12 WARRANTY 37 IT EN ...

Страница 4: ... assicurarsi che l impianto di alimentazione del veicolo sia in buono stato In caso di cavi di collegamento danneggiati o di sezione inadeguata effettuare immediatamente la sostituzione avvalendosi di tecnici qualificati NON utilizzare il dispositivo con cavi danneggiati e o di sezione inadeguata In caso di anomalie nella conformità del prodotto non utilizzarlo è severamente vietato aprire il disp...

Страница 5: ...n N 1 Estensione cavo di alimentazione IEC non presente in tutti i modelli 3 DESCRIZIONE POWERCHARGERPRO è il caricabatterie professionale con selettore di curva di carica e Led di stato costruito con elettronica di qualità microcontrollore evoluto e materiali resistenti all uso intensivo POWERCHARGERPRO è adatto a batterie 12V con tecnologia AGM Gel Acido Libero e Litio LiFePO4 24V con tecnologia...

Страница 6: ...elli è presente una coppia di cavi che portano il segnale pulito di un relè 4 N PIN CONNESSIONE 1 Connessione bipolare da collegare ai poli positivo e negativo della batteria da ricaricare 2 Contatto pulito di un relè per effettuare collegamento Led di stato remoto 3 Led di stato 4 Presa IEC o spina Schuko per collegamento rete elettrica esterna 230V 1 4 2 3 ...

Страница 7: ...eria in dotazione e per impostarla è necessario agire sui selettori del Dip Switch posto internamente Per accedere ai selettori del Dip Switch è necessario rimuovere il tappo in plastica posto su uno dei lati di POWERCHARGERPRO come da illustrazione seguente Una volta rimosso il tappo in plastica agire delicatamente sui selettori del Dip Switch selezionando la curva desiderata come da tabelle segu...

Страница 8: ...A BATTERIA 5 IUIa Desolfatazione ON AGM 6 IUUa Desolfatazione OFF Generica Gel AGM Default 7 IUIa Desolfatazione ON Gel e Acido libero generico 8 IUIa Desolfatazione ON Acido Libero uso trazione off off off on on on off on off off off on on on off on 1 OFF 2 OFF 1 ON 2 ON 1 ON 2 OFF 1 OFF 2 ON CONFIGURAZIONI VALIDE PER I MODELLI PFC0300 12CH15S PFC0600 12CH25S PFC0600 12CH20S CONFIGURAZIONI VALIDE...

Страница 9: ...ing curves below refer to the configurations on page 8 7 CURVE 1 e 5 CURVE 2 e 6 BULK I1 Imax V1 2 35 2 45Vpc V 2 3Vpc ABSORPTION FLOATING Tempo V I BULK I1 Imax V1 2 465 0 15Vpc V2 2 60Vpc I2 max 16 I1 ABSORPTION DESULPHATION Tempo V I ...

Страница 10: ...8 CURVA 7 CURVA 3 BULK I1 Imax 2 35Vpc V2 2 6Vpc Errore inter ruzione 2 8V V 2 3Vpc Fase I2 Max 16 I1 ABSORPTION DESULPHATION FLOATING Tempo V I BULK I1 Imax V1 14 5V ABSORPTION Tempo V I ...

Страница 11: ... necessario è possibile fissare il dispositivo con delle viti sfruttando le flange laterali Successivamente vanno effettuati i collegamenti elettrici secondo lo schema seguente 9 CURVE 4 e 8 BULK I1 Imax V1 2 35Vpc 2 45Vpc V2 2 45 2 7V V 2 25Vpc Fase I2 Max 1 3 C20 ABSORPTION DESULPHATION FLOATING Tempo V I ...

Страница 12: ...ulito di un relè per la segnalazione remota della presenza di corrente elettrica esterna 230V Questo segnale permette di capire anche a distanza dal dispositivo se le batterie sono in carica Seguire gli schemi seguenti per effettuare il collegamento corretto 10 LED E RESISTENZA ...

Страница 13: ...11 LAMPADINA AUTOMOTIVE ...

Страница 14: ...iega la relazione tra colore del led e stato del sistema 12 SEGNALE SIGNIFICATO Led Rosso fisso o lampeggiante Allarme collegamento con polarità invertita oppure tensione troppo alta Led Giallo Fisso Batteria in Carica Led Giallo lampeggiante Batteria non connessa o batteria con tensione troppo bassa Led Giallo Led Verde fissi Batteria in desolfatazione Led Verde fisso Carica ultimata ...

Страница 15: ...otezioni aggiuntive Connessione sicura Protezione sovratemperatura Dimensioni 106x128x56 5mm Peso 650g cavi esclusi PFC0300 12CH15S Tensione nominale di ingresso 100 240Vac 10 universale Tensione nominale di uscita 12V Corrente di uscita 15A 0 5A Frequenza 50 60Hz Bulk Charge 14 4V 2 4V Cell Floating Charge 13 5V 13 9V 2 27V Cell Protezione cortocircuito Autoripristino al termine della condizione ...

Страница 16: ...ive Connessione sicura Protezione sovratemperatura Dimensioni 223 2x128x56 5mm Peso 2120g cavi esclusi PFC0600 12CH25S Tensione nominale di ingresso 100 240Vac 10 universale Tensione nominale di uscita 12V Corrente di uscita 25A 0 5A Frequenza 50 60Hz Bulk Charge 14 4V 2 4V Cell Floating Charge 13 5V 13 9V 2 27V Cell Protezione cortocircuito Autoripristino al termine della condizione di cortocircu...

Страница 17: ...tive Connessione sicura Protezione sovratemperatura Dimensioni 145x128x56 5mm Peso 1330g cavi esclusi PFC0600 24CH15S Tensione nominale di ingresso 100 240Vac 10 universale Tensione nominale di uscita 24V Corrente di uscita 15A 0 5A Frequenza 50 60Hz Bulk Charge 28 8V 2 4V Cell Floating Charge 27V 27 8V 2 27V Cell Protezione cortocircuito Autoripristino al termine della condizione di cortocircuito...

Страница 18: ...ive Connessione sicura Protezione sovratemperatura Dimensioni 223 2x128x56 5mm Peso 2120g cavi esclusi PFC1200 24CH30S Tensione nominale di ingresso 100 240Vac 10 universale Tensione nominale di uscita 24V Corrente di uscita 30A 0 5A Frequenza 50 60Hz Bulk Charge 28 8V 2 4V Cell Floating Charge 27V 27 8V 2 27V Cell Protezione cortocircuito Autoripristino al termine della condizione di cortocircuit...

Страница 19: ... Charge 43 2V 2 4V Cell Floating Charge 40 5V 41 7V 2 27V Cell Protezione cortocircuito Autoripristino al termine della condizione di cortocircuito Protezione inversione di polarità Autoripristino al termine della condizione di inversione Protezioni aggiuntive Connessione sicura Protezione sovratemperatura Dimensioni 280x134x77 2mm Peso 3130g cavi esclusi ...

Страница 20: ...4 Sì per i modelli P F C 0 3 0 0 1 2 C H 1 5 S P F C 0 6 0 0 1 2 C H 2 0 S PFC0600 12CH25S No per i modelli P F C 0 1 5 0 1 2 C H 1 0 S P F C 0 3 0 0 2 4 C H 1 0 S P F C 0 6 0 0 2 4 C H 1 5 S P F C 0 6 0 0 2 4 C H 2 0 S PFC1200 24CH30S PFC1200 36CH25S 18 ...

Страница 21: ..._____________________________________________ Timbro e firma del rivenditore modello__________________________________ MATRICOLA_________________________________ DATA ACQUISTO_____________________________ Presto il consenso per L attività di cui al punto 3 c della informativa presente su www ndsenergy it privacy policy NDS ENERGY S r l Via G Pascoli 96 98 65010 Cappelle sul Tavo PE Italy email cus...

Страница 22: ...20 ...

Страница 23: ...ery humid environments in contact with water splashes various liquids or exposed to rain To avoid risk of electric shock and or fire the vehicle s fuel system must be in good condition In case of damaged connecting cables or inadequate section immediately replace them with suitable cables as specified by this manual or by a qualified electrician In case of anomalies in the conformity of the produc...

Страница 24: ... IEC power cable extension not all models 3 DESCRIPTION POWERCHARGERPRO is the professional charger with charging curve selector and status LED built with quality electronics advanced microcontroller and intensive use resistant materials POWERCHARGERPRO is suitable for batteries 12V with technology AGM Gel Wet and Lithium LiFePO4 24V with technology AGM Gel Wet Three LEDs indicate the device statu...

Страница 25: ... and in some models there is a pair of cables carrying potential free contact of a relay 23 1 4 2 3 N PIN CONNECTION 1 Positive and negative electrical connection for battery to be charged 2 Potential free contact of a relay for the remote status led connection 3 Status Leds 4 IEC socket or Schuko socket for main hookup ...

Страница 26: ... to the battery type to set it it is necessary to act on the Dip Switch selectors located internally To access the Dip Switch selectors it is necessary to remove the plastic cap located on one side of the POWERCHARGERPRO as shown below Once the plastic cap has been removed act gently on the Dip Switch selectors selecting the desired curve as shown in the tables below 24 1 2 ...

Страница 27: ...ulphation OFF Generica Gel AGM Default 7 IUIa Desulphation ON Gel e Wet generico 8 IUIa Desulphation ON Wet Traction use SETTINGS VALID FOR THE FOLLOWING MODELS PFC0300 12CH15S PFC0600 12CH25S PFC0600 12CH20S SETTINGS VALID FOR THE FOLLOWING MODELS PFC0150 12CH10S PFC0600 24CH20S PFC0300 24CH10S PFC1200 24CH30S PFC0600 24CH15S PFC1200 36CH25S 1 OFF 2 OFF 1 ON 2 ON 1 ON 2 OFF 1 OFF 2 ON off off off...

Страница 28: ...arging curves below refer to the configurations on page 28 26 CURVES 1 e 5 CURVES 2 e 6 I1 Imax V1 2 465 0 15Vpc V2 2 60Vpc I2 max 16 I1 Time V I BULK ABSORPTION RECONDITIONING BULK I1 Imax V1 14 5V V 13 7V ABSORPTION FLOATING Time V I ...

Страница 29: ...27 CURVE 7 CURVE 3 BULK ABSORPTION RECONDITIONING FLOATING I1 Imax 2 35Vpc V2 2 6Vpc Error inter rupt 2 8V V 2 3Vpc I2 phase Max 16 I1 Time V I BULK I1 Imax V1 14 5V ABSORPTION Time V I ...

Страница 30: ...arged if necessary the device can be fixed with screws using the side flanges Then the electrical connections must be made according to the following diagram 28 CURVES 4 e 8 BULK I1 Imax V1 2 3Vpc 2 45Vpc V2 2 45 2 7V V 2 25 2 7Vpc I2 phase Max 1 3 C20 ABSORPTION RECONDITIONING FLOATING Time V I ...

Страница 31: ...ree contact of a relay for a remote status LED connection that shows the external 230V electricity presence This signal allows to understand even remotely from the device if the batteries are charging Follow the diagrams below to make the correct connection 29 LED AND RESISTOR ...

Страница 32: ...30 CAR BULB ...

Страница 33: ...relationship between LED color and system status 31 SIGNAL MEANING Red LED Steady or Flashing Alarm connection with reversed polarity or voltage too high Yellow LED Steady Battery in charge Yellow LED Flashing Battery not connected or battery with too low voltage Yellow LED Green LED Steady Battery in desulphation mode Green LED Steady Charge completed ...

Страница 34: ...dditional protections Safe connection Over temperature protection Size 106x128x56 5mm Weight 650g without cables PFC0300 12CH15S Input Nominal Voltage 100 240Vac 10 universal Output Nominal Voltage 12V Output Current 15A 0 5A Frequency 50 60Hz Bulk Charge 14 4V 2 4V Cell Floating Charge 13 5V 13 9V 2 27V Cell Short circuit protection Automatic reset at the end of the short circuit condition Invers...

Страница 35: ...tections Safe connection Over temperature protection Size 223 2x128x56 5mm Weight 2120g without cables PFC0600 12CH25S Input Nominal Voltage 100 240Vac 10 universal Output Nominal Voltage 12V Output Current 25A 0 5A Frequency 50 60Hz Bulk Charge 14 4V 2 4V Cell Floating Charge 13 5V 13 9V 2 27V Cell Short circuit protection Automatic reset at the end of the short circuit condition Inverse polarity...

Страница 36: ...otections Safe connection Over temperature protection Size 145x128x56 5mm Weight 1330g without cables PFC0600 24CH15S Input Nominal Voltage 100 240Vac 10 universal Output Nominal Voltage 24V Output Current 15A 0 5A Frequency 50 60Hz Bulk Charge 28 8V 2 4V Cell Floating Charge 27V 27 8V 2 27V Cell Short circuit protection Automatic reset at the end of the short circuit condition Inverse polarity pr...

Страница 37: ...tections Safe connection Over temperature protection Size 223 2x128x56 5mm Weight 2120g without cables PFC1200 24CH30S Input Nominal Voltage 100 240Vac 10 universal Output Nominal Voltage 24V Output Current 30A 0 5A Frequency 50 60Hz Bulk Charge 28 8V 2 4V Cell Floating Charge 27V 27 8V 2 27V Cell Short circuit protection Automatic reset at the end of the short circuit condition Inverse polarity p...

Страница 38: ...S PFC1200 36CH25S 36 PFC1200 36CH25S Input Nominal Voltage 100 240Vac 10 universal Output Nominal Voltage 36V Output Current 25A 0 5A Frequency 50 60Hz Bulk Charge 43 2V 2 4V Cell Floating Charge 40 5V 41 7V 2 27V Cell Short circuit protection Automatic reset at the end of the short circuit condition Inverse polarity protection Automatic reset at the end of the inverse polarity condition Additiona...

Страница 39: ...__________________________________________ stamp and signature of the seller model_____________________________________ SERIAL NUMBER_____________________________ Purchase date_____________________________ I CONSENT TO THE ACTIVITY DESCRIBED IN POINT 3 C OF THE INFORMATION NOTICE ON www ndsenergy it privacy policy NDS ENERGY S r l Via G Pascoli 96 98 65010 Cappelle sul Tavo PE Italy email customer...

Страница 40: ...SERVE ALL THE ENERGY YOU NEED 0042_MANS_ PowChPro_IT_GB03 NDS ENERGY s r l Via Pascoli 96 98 65010 Cappelle sul Tavo Pe Italy Tel 39 085 4470396 web www ndsenergy it email customer ndsenergy it LIKE US facebook com ndsenergysrl ...

Отзывы: