NDS 90R0123 Скачать руководство пользователя страница 27

 Terms and Conditions | 21

Terms and Conditions

Declarations of Conformity

FCC and Council Directives of European Standards

This device complies with Part 15 of FCC rules and 2017/745 Medical Device Regulation of European Union.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesirable results.

1. Use the attached specified cables with the color monitor so as not to interfere with radio and television

reception. Use of other cable and adapters may cause interference with other electronic equipment.

2. This equipment has been tested and found to comply with the limits pursuant to FCC part 15 and CISPR 11.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.

IEC

This equipment has been tested and found to comply with the limits for medical devices to the IEC 60601-1-2.
These limits are designed to provide reasonable protection against harmful interference in a typical medical
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to other devices in the vicinity.

FCC, Council Directives of European Standards, and IEC:

There is no guarantee that interference will not occur in an installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult your dealer or an experienced radio/TV technician for help.

Accessory equipment connected to this product must be certified according to the respective IEC Standards (i.e.,
IEC 60950-1 or IEC 62368-1) for data processing equipment and IEC 60601-1 for medical equipment.
Furthermore, all configurations shall comply with the system standard, IEC 60601-1-1. Anyone who connects
additional equipment to the signal input part or signal output part configures a medical system and is therefore
responsible that the system complies with the requirements of system standard IEC 60601-1-1. Whoever is
responsible for securing the unit to a system needs to ensure that the mounting equipment used with this
product complies to IEC standard 60601-1. If in doubt, consult the technical services department or your local
representative.

FCC

Note: 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant

to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures: 

• Reorient or relocate the receiving antenna. 

• Increase the separation between the equipment and receiver. 

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

• Consult the dealer or an experienced radio/TV technician for help.

Содержание 90R0123

Страница 1: ...Radiance Ultra 4K UHD 32 USER MANUAL ENGLISH ...

Страница 2: ......

Страница 3: ...e without notice NDS provides this information as reference only Reference to products from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDS All trademarks are the property of the...

Страница 4: ......

Страница 5: ...u 8 Connector Panel 9 Radiance Ultra 4K UHD Connector Panel Standard 90R0132 9 Standard Configuration 9 Connector Types 9 Radiance Ultra 4K UHD Connector Panel 12G SDI 90R0123 and 90R0125 9 12G SDI Configuration 9 Connector Types 9 Electrical Symbols 10 Cable Bend Radius 10 Specifications 11 Supported Resolutions 12 DisplayPort 12 DVI 1 and DVI 2 12 HDMI 1 13 HDMI 2 14 12G SDI 14 Installation and ...

Страница 6: ......

Страница 7: ...er s European Community representative This symbol indicates compliance with the Waste Electrical and Electronic Equipment Directive WEEE Directive This symbol indicates the device is a Medical Device This product is intended only for use by healthcare professionals in professional healthcare environments This product is T U V approved with respect to electric shock fire and mechanical hazards onl...

Страница 8: ...isted safety standards only when used with the supplied medical grade power supply Power Cord Use a hospital grade power cord with the correct plug for your power source Disconnect the power cord from the AC mains The power cord is the only recognized disconnect device MEDICAL EQUIPMENT should be positioned so that the disconnect device is readily accessible Monitors should be powered from a cente...

Страница 9: ... with details of the current input listed above the menu tabs SCROLL Button Vertical Selection Control To enter a menu tap the SCROLL button The top parameter row is selected with first tap of the SCROLL button and the selection moves downward to the next row with each successive tap To exit a menu use the SCROLL button to move the selection to the bottom menu row and then tap the SCROLL button ju...

Страница 10: ...ons Sharpness To adjust sharpness edge enhancement of the displayed image tap the or buttons 50 default value displays the image as received 50 increasing values sharpen the image 50 decreasing values soften the image Overscan To select an overscan setting tap the or buttons 0 The image is displayed at a size that fills the screen without losing any video information Image could be displayed as le...

Страница 11: ... tap the or buttons Off No screen orientation change 180 Rotates the screen 180 V Flip Rotates the screen vertically 180 H Flip Rotates the screen horizontally 180 Rotation OSD The rotation OSD option displays the screen orientation indicator on the screen at the selected interval Select the screen rotation indication option Off On 10 seconds Blink ...

Страница 12: ...YUV inputs To adjust saturation color intensity of the image tap the or buttons Hue available only for YUV inputs To adjust hue color of the image tap the or buttons Brightness To darken or lighten the image tap the or buttons Contrast To adjust contrast of the image tap the or buttons Video Level To select a video level setting tap the or buttons Normal The incoming signal is displayed without mo...

Страница 13: ...access to all OSD menus except the Input Menu The OSD Menu closes and a MENU LOCKED message displays briefly To unlock OSD access simultaneously press the MENU and SCROLL buttons until the MENU UNLOCKED message displays Backlight To adjust the backlight level of the display tap the or buttons Backlight Stabilization To enable or disable backlight stabilization tap the or buttons Off Default settin...

Страница 14: ...ncoming signal is either preprocessed 3D at UHD Line by Line format or a standard two dimensional image and not three dimensional Line by Line Select this option if the incoming signal is three dimensional in a line by line format Top Bottom Select this option if the incoming signal is three dimensional in a top bottom format Color Domain Format The following settings are available on all inputs A...

Страница 15: ...es 1 12G SDI IN input accepts a 12G SDI signal to display as UHD image 2 12G SDI OUT output is active only with monitor powered on and signal applied to 12G SDI 3 The Service 1 and Service 2 USB connectors are designated for installing firmware upgrades 4 RS 232 6 pin modular connector used for Unified Serial Command USC input Inputs Connector Types Inputs Connector Types Outputs Connector Types 1...

Страница 16: ...ff switch Open Off Switch This symbol appears on the open or off side of the display On Off switch Cable Bend Radius We recommend that the bend radius of metallic cables be no less than 2 5 inches 63 mm or 7 times the diameter of the cable whichever is greater The bend radius of Fiber Optic cables should be no less than 10 times the diameter of the cable Sharper bends can damage the cable and or d...

Страница 17: ...5 mm DC Input 24 V 6 25 A 24 V 6 25 A 24 V 6 25 A DC Power Consumption Typical a 130 W 130 W 120 W Monitor Weight 32 0 lb 14 5 kg 32 0 lb 14 5 kg 32 0 lb 14 5 kg Monitor Dimensions W x H x D 30 7 x 20 x 3 4 780 x 509 x 87 mm 30 7 x 20 x 3 4 780 x 509 x 87 mm 30 7 x 20 x 3 4 780 x 509 x 87 mm Temperature Ranges Operating 32 104 F 0 40 C 32 104 F 0 40 C 32 104 F 0 40 C Storage Transport 4 122 F 20 5...

Страница 18: ...Horizontal Resolution pixels Vertical Resolution lines Vertical Frequency Hz Horizontal Resolution pixels Vertical Resolution lines Vertical Frequency Hz SD Video Modes Graphic Modes 720 480p 60 640 480 60 720 576p 50 800 600 75 HD Video Modes 1024 768 60 004 1280 720p 25 1024 768 70 069 1280 720p 29 97 1024 768 75 029 1280 720p 30 1152 864 75 1280 720p 50 1280 800 59 910 1280 720p 59 94 1280 1024...

Страница 19: ...HD Video Modes 1920 1080p 25 800 600 56 25 1280 720p 25 1920 1080p 29 97 800 600 60 317 1280 720p 29 97 1920 1080p 30 800 600 75 1280 720p 30 1920 1080p 50 1024 768 60 004 1280 720p 50 1920 1080p 59 94 1024 768 70 069 1280 720p 59 94 1920 1080p 60 1024 768 75 029 1280 720p 60 UHD Video Modes 1152 864 75 3840 2160p 24 1280 800 59 91 3840 2160p 25 1280 1024 60 02 3840 2160p 29 97 1280 1024 75 025 38...

Страница 20: ...280 1024 60 02 1280 720p 60 UHD Video Modes 1280 1024 75 025 4K Video Modes 3840 2160p 24 1280 1024 85 024 4096 2160p 30 3840 2160p 25 1600 1200 60 4096 2160p 50 3840 2160p 29 97 1400 1050 59 948 4096 2160p 59 94 3840 2160p 30 1400 1050 59 978 4096 2160p 60 3840 2160p 50 1440 900 59 902 3840 2160p 59 94 1440 900 59 888 3840 2160p 60 1920 1200 59 950 Horizontal Resolution pixels Vertical Resolution...

Страница 21: ... an ammonia based glass cleaner or any of the following disinfectants Warning Do not allow liquids to enter the interior of the monitor as severe damage to the unit can result Do not use solvents abrasive detergents or chemical cleaning cloths Maintenance Requirements This monitor does not require any major maintenance other than periodic cleaning of the front glass and enclosure Troubleshooting G...

Страница 22: ...16 Troubleshooting ...

Страница 23: ...edical devices prior to a surgical procedure The emissions characteristics of this equipment make it suitable for use in industrial areas and hospitals CISPR 11 class A If it is used in a residential environment for which CISPR 11 class B is normally required this equipment might not offer adequate protection to radio frequency communication services The user might need to take mitigation measures...

Страница 24: ... are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B The product is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations fli...

Страница 25: ...t is intended for use in the electromagnetic environment specified below The customer or the user of the product should assure that it is used in such an environment Immunity Test Immunity Test Electrostatic discharge ESD IEC 61000 4 2 2 4 6 8kV contract discharge 2 4 6 8 15 kV air discharge Radiated RF field IEC 61000 4 3 3 V m 80 MHz 2 7 GHz 80 AM 1 kHz Proximity fields from wireless transmitter...

Страница 26: ...uipment could result For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the high...

Страница 27: ...tween the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult your dealer or an experienced radio TV technician for help Accessory equipment connected to this product must be certified according to the respective IEC Standards i e IEC 60950 1 or IEC 62368 1 for data processing equipment and IEC 60601 1 for medical ...

Страница 28: ...IONS AND OR GUARANTEES OF ANY TYPE NATURE OR EXTENT BE IT IMPLIED EXPRESS AND OR WHETHER ARISING UNDER OR AS A RESULT OF ANY STATUTE LAW COMMERCIAL USAGE CUSTOM TRADE OR OTHERWISE ARE HEREBY EXPRESSLY EXCLUDED AND DISCLAIMED NDS its suppliers and or distributors are not liable directly or by way of indemnity for any special incidental consequential punitive exemplary or indirect damages including ...

Страница 29: ......

Страница 30: ...many 49 89 31 707 100 info novanta europe novanta com Asia Pacific Novanta Japan East Square Omori 6 20 14 Minamioi Shinagawa ku Tokyo 140 0013 Japan 81 3 5753 2466 info ndssi com Oriental Media Center Suite 2302 Tower C No 4 Guang Hua Road Chao Yang District Beijing 100026 China 86 10 8559 7859 info ndssi com NDS Quality System ISO 13485 FDA Registration 2954921 February 2021 ...

Отзывы: