2010-10-26
Network Design and Engineering Guide
125
Data Networking
SkyWAN
®
Frame Relay Networking Features
4.3
SkyWAN
®
Frame Relay Networking Features
On the serial user ports of the UIM board
Sky
WAN
®
IDU supports Frame Relay networking.
The IDU acts as a Frame Relay switch, providing a User-to-Network (UNI) or Network-to-Net-
work (NNI) service on these interfaces. Besides standard FR services according to the Frame
Relay Forum UNI and NNI standards,
Sky
WAN
®
additionally supports the following features:
-
FR multicast connections.
-
Sky
WAN
®
FAD service: Supports service differentiation over a single virtual circuit if a
Sky-
WAN
®
FAD is connected to the serial interface.
-
Isochronous FRAD service: Provides a bit transparent data service between IDU serial
ports in either a point-to-point or point-to-multipoint fashion. In this case, the Frame Relay
functionality is only used inside the
Sky
WAN
®
network, for the connected devices it is just
a transparent serial data connection.
4.3.1
Serial port properties
Sky
WAN
®
IDU 7000 / 2x70 have 4 serial frame relay ports on the UIM board. Some or all of
these ports may be activated, if their usage is included in the software license. The following
table 4-5 displays the possible port types.
Table 4-5
UIM Board FR Serial Port Types
The interface standard is defined by the selected cable type. Note that there are special cable
types available for a
Sky
WAN
®
IDU-FAD connection.
Each port type supports port speeds 2.4, 4.8, 9.6, 19.2 and 38.4 Kbit/s. The port types X.21,
EIA-232 and V.35 support additionally port speeds of 48, 56, 64, 128, 192, 256, 384, 512, 768,
1024, 1636, 2048, 3072 and 6144 Kbit/s. Note that the port speeds 3072 and 6144 kbps are
not available for ports which are used for a isochronous FRAD service.
Each port can be configured for one of the following port types:
-
FR-UNI: For connection to a Frame Relay Access Device like
Sky
WAN
®
FAD or a Rout-
er with a serial FR interface.
-
FR-NNI: For connection to another FR switch to interconnect to a terrestrial FR network
or to another
Sky
WAN
®
network.
-
Isochronous FRAD: For connection to a device which does not support the Frame Relay
protocol but needs a transparent serial data connection.
Interface
X.21
EIA-449
EIA-232
V.35
Procedural
X.21
V.24
V.24
V.24
Functional
X.24
V.24
V.24
V.24
Electrical
X.27
V.36 (EIA-449)
V.28
V.35
Mechanical
IDU DTE: male
IDU DCE: female
ISO 4903
15 pins
ISO 4902
37 Pins
ISO 2110
25 pins
ISO 2593
34 pins
Label DTE:
W56
DCE: W57
DTE: W52
DCE: W53
DTE: W50
DCE: W51
DTE: W54
DCE: W55
Содержание SKYWAN IDU 7000
Страница 1: ......
Страница 2: ......
Страница 6: ...Page intentionally left blank 2 Network Design and Engineering Guide 2010 10 26...
Страница 12: ...Page intentionally left blank 8 Network Design and Engineering Guide 2010 10 26...
Страница 16: ...Page intentionally left blank 12 Network Design and Engineering Guide 2010 10 26...
Страница 22: ...Page intentionally left blank 18 Network Design and Engineering Guide 2010 10 26...
Страница 76: ...Page intentionally left blank 72 Network Design and Engineering Guide 2010 10 26...
Страница 134: ...Page intentionally left blank 130 Network Design and Engineering Guide 2010 10 26...
Страница 138: ...Page intentionally left blank 134 Network Design and Engineering Guide 2010 10 26...
Страница 144: ...Page intentionally left blank 140 Network Design and Engineering Guide 2010 10 26...
Страница 153: ......
Страница 154: ...www ndsatcom com...