![NCT 90 Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/nct/90/90_manual_714927034.webp)
31
L8000 THIS MINI PLC PROGRAM IS LOADED FROM PROM! (V.1.50) (c) NCT
1st level module called in each 20ms
:001
(V003ANI003)
;falling edge of emergency stop line
D404
;mavhine on output disable
PBE"ESTOP?"
;calling blinking error message
C003
;calling emergency stop module
Z
(NI402ONI411)
;not reference point return mode or
;not
start
state:
limit
switches
are
;considered as they are
NI006
U417
;sets X on + limit switch flag
E
D417
Z
NI004
U416
;sets X on - limit switch flag
E
D416
Z
NI001
U415
;sets y on + limit switch flag
E
D415
Z
NI000
U414
;sets y on - limit switch flag
E
D414
Z
NI007
U413
;sets Z on + limit switch flag
E
D413
Z
NI005
U412
;sets Z on - limit switch flag
E
D412
Z
Z
;<--
end of condition: not reference point
;return mode or not start state
(I006AI004)
;limit switches of X axis are considered as
;reference point switches
U430
;X is not on referenece switch
E
D430
;X is on referenece switch
Z
(I000AI001)
;limit switches of y axis are considered as
;reference point switches
U431
;y is not on referenece switch
E