X-Series Integrated Keypad

9

9. Reinstall the Display Collar on the terminal.

10. Connect the Keypad USB Cable to the PCB.

11. Connect the Keypad Ground Wire under the PCB mounting screw.

12. Replace the Base Stand and Rear Cover assembly on the display.

Содержание X Series

Страница 1: ...KIT INSTRUCTIONS X Series Integrated Keypad 7702 K149 K349 Issue D...

Страница 2: ...It is the policy of NCR Corporation NCR to improve products as new technology components software and firmware become available NCR therefore reserves the right to change specifications without prior...

Страница 3: ...Black Qty 1 1x1 Keytip Lens Qty 1 1x1 5 Keytip Lens Qty 11 2x1 5 Keytip Lens Qty 1 K349 Keytip Dimensions Keytip Keytip Top Size mm Label size mm Height Width Corner Radius Height Width Corner Radius...

Страница 4: ...7 XR7 Plus POS 1 Lay the terminal face down on a flat surface using a protective foam cloth 2 Remove the Base Stand and Rear Cover assembly a Loosen the captive screws 2 that secure the Rear Cover to...

Страница 5: ...isplay Collar 9 screws 4 Remove the Blank Plate left side of terminal right side is for MSR from the Display Collar The plate is connected to the Display Collar with a strong adhesive Use care when re...

Страница 6: ...rated Keypad 5 Install the Keypad onto the Display Collar 2 screws 6 Route the Keypad Cable through the Cable Guide on the Display Collar Note Limit the amount of cable from the Cable Guide to 2 5 for...

Страница 7: ...on the terminal 8 Connect the Keypad Cable and Ground Wire to the Motherboard Caution Pull up and down on the cable at the Cable Guide to make sure they are not pinched under the Display Collar 9 Rep...

Страница 8: ...eries Displays 1 Lay the terminal face down on a flat surface Caution Always use a soft material cloth foam to protect the display screen when placing the terminal face down 2 Remove the screws 4 that...

Страница 9: ...X Series Integrated Keypad 7 3 Remove the Rear Cover screws 2 4 Pivot the Rear Cover as shown to remove it 5 Remove the Display Collar 9 screws...

Страница 10: ...is for MSR from the Display Collar The plate is connected to the Display Collar with a strong adhesive Use care when removing it to not damage the Display Collar 7 Install the Keypad onto the Display...

Страница 11: ...pad 9 9 Reinstall the Display Collar on the terminal 10 Connect the Keypad USB Cable to the PCB 11 Connect the Keypad Ground Wire under the PCB mounting screw 12 Replace the Base Stand and Rear Cover...

Страница 12: ...Dynakeys The utility is located in the following location http www5 ncr com support support_drivers_ patches asp Class External NCRKeyboard Remap display Refer to the Readme document for the utility i...