Chapter 2:
Site Preparation
Physical Environment
Operating Range
Condition Range
Temperature
5°
to
45°C
Relative
Humidity
10%
to
90%
(Non
‐
condensing)
Storage Range
Condition Range
Temperature
‐
10°
to
50°C
Relative
Humidity
10%
to
90%
Transit Range
Condition Range
Temperature
‐
40°
to
60°C
(One
‐
week
max.)
Relative
Humidity
5%
to
95%
Electrical Environment
Power
is
supplied
to
the
display
either
from
an
external
power
supply
or
through
a
Powered
USB
interface.
In
either
case,
the
nominal
input
voltage
shall
be
+12
volts
and
conform
to
the
following:
Parameter Minimum Typical Maximum
Input
Voltage
+10.8
V
+12.0
V
+13.2
V
Power Consumption
Parameter Typical
Standby
Input
Power
+16.3
W
+1.1
W
Weight
2.1
kg
(4.8
lbs.)