5-10
Chapter 5: Calibration
Display
Add Weight
Remove Weight
Ready C-5.00 lb (2.500 kg)
5.00 lb. (2.500 kg)
Ready C-15.00 lb (5.000 kg)
10.00 lb. (2.500 kg)
Ready C-30.00 lb (10.000 kg) 15.00 lb. (5.00 kg)
Ready C-0.00 lb (0.000 kg)
30.00 lb. (10.000 kg)
Ready 0.00 lb (0.000 kg)
Note:
Use the same kilogram weights for both 9.995 kg and 13.995 kg
scale units.
6.
Press Reset/Scale Zero button. Display will indicate Ready C 5.00
lb
(or 2.500 kg).
7.
Place a 5.00 lb (or 2.500 kg) weight in center of Top Plate.
8.
Press Reset/Scale Zero button. Display will indicate Ready C 15.00
lb
(5.000 kg).
9.
Add a 10.00 lb (2.500 kg) weight in center of Top Plate. Total
weight on scale should be 15 lbs. (5.00 kg).
10.
Press Reset/Scale Zero button. Display will indicate Ready C 30.00
lb
(10.000 kg).
11.
Add a 15.00 lb (5.000 kg) weight in center of Top Plate. Total
weight on scale should be 30.00 lbs (10.000 kg).
12.
Press Reset/Scale Zero button. Display will indicate Ready C 0.00
lb
(0.000 kg).
13.
Remove all weights.
14.
Press Reset/Scale Zero button. Verify display indicates Scale
Ready 0.00 lb
(0.000 kg).
15.
Press and holdReset/ Scale Zero button. Record Cal and Par
values.
16.
The Cal value should be incremented by one, indicating that a
calibration has been performed. The PAr value should remain
unchanged.
Содержание 7870
Страница 1: ...NCR 7870 Scanner Scale Release 1 0 User s Guide BST0 2121 90 Issue G...
Страница 42: ...2 18 Chapter 2 Features Functions and Kits...
Страница 86: ...4 12 Chapter 4 Installation...
Страница 104: ...5 18 Chapter 5 Calibration...
Страница 116: ...6 12 Chapter 6 Operation...
Страница 194: ...7 78 Chapter 7 Programming...
Страница 199: ...8 6 Chapter 8 Troubleshooting...
Страница 221: ...A 22 Appendix A Programming Worksheets...
Страница 228: ...BST0 2121 90 Nov 1999 Printed on recycled paper...