7459-K180 1
Introduction
This
kit
provides
the
components
to
add
an
integrated
UPS
Battery
to
a
7457,
7459,
or
7606
terminal.
This
feature
can
only
be
installed
in
terminals
that
are
equipped
with
a
UPS
Power
Supply.
7457
‐
3xxx
7457
‐
4xxx
7459
‐
5110
7606
‐
1110
COM Port Considerations
The
methods
used
to
provide
the
port
assignments
for
the
UPS
are
different
between
the
7457
‐
3xxx
and
7457
‐
4xxx
terminals.
3xxx
‐
has
a
dedicated
COM5
port
which
can
only
be
used
for
the
UPS.
4xxx
‐
The
UPS
takes
the
place
of
one
of
the
existing
COM
ports
(COM3
or
COM4),
depending
on
which
connector
on
the
motherboard
is
used
(Factory
default
is
COM4).
The
UPS
uses
the
IRQ
and
ADDRESS
of
the
port
that
it
replaced,
i.e.
you
loose
functionality
for
that
particular
serial
port
).
7459
‐
5xxx
–
The
UPS
connects
directly
to
a
connector
on
the
Motherboard
and
uses
COM4.
Since
both
the
UPS
and
the
Extended
I/O
Board
use
COM4
they
cannot
be
used
at
the
same
time.
7606
‐
1110
–
The
UPS
connects
directly
to
a
connector
on
the
Motherboard
and
uses
COM4.
Since
both
the
UPS
and
the
Extended
I/O
Board
use
COM4
they
cannot
be
used
at
the
same
time.