CR5000 Coin Recycler Type D Validator

Module

The CR5000 Coin Recycler Type D Validator Kit supports the Euro 7360 (R6-C)
Preferred Offer that requires converting units from Euro currency to Czech support.
The conversion involves removing existing Type B Validator Module and installing
Type D Validator Module. This publication provides procedures for replacing a Type
B Validator Module with a Type D Validator Module in an NCR FastLane SelfServ™
Checkout (7360).

Kit Contents

Part Number

Description

497-0531920

7360-K991 CR5000 Coin Recycler Type D Validator Module

497-0526625

Crane XChange Validator Type D

*

497-0423108

Instructions - Kit (Reference Sheet)

* Items marked with an asterisk are not called out on the image.

Содержание 7360-K991

Страница 1: ...Kit Instructions CR5000 Coin RecyclerType D Validator Module 7360 K991 Issue A...

Страница 2: ...documentation is permitted under the terms and conditions of an agreement you have with NCR NCR s copyright notice must be included It is the policy of NCR Corporation NCR to improve products as new...

Страница 3: ...iii Revision Record Issue Date Remarks A Nov 2021 First issue...

Страница 4: ...dator Module and installing Type D Validator Module This publication provides procedures for replacing a Type B Validator Module with a Type D Validator Module in an NCR FastLane SelfServ Checkout 736...

Страница 5: ...ocedures To convert units from Euro currency to Czech support replace the existing Type B Validator Module with a Type D Validator Module by doing the following procedures Removing the Validator Modul...

Страница 6: ...emoving the Validator Module To remove the existing Validator Module follow these steps 1 Access the CR5000 Coin Recycler cpi 2 Turn the Service screw located behind the Validator on the CR5000 Coin R...

Страница 7: ...module as shown below Ensure that the connector and cable are not strained Warning The validator is connected to the chassis using a short length cable with a non latching connector end Ensure that t...

Страница 8: ...ve the existing Validator Module For more information refer to Removing the Validator Module on page 3 2 Connect the cable to the Validator connector 3 Place the Validator Module onto the CR5000 Chass...

Страница 9: ...ype D Validator Module 4 Turn the Service screw located behind the Validator on the CR5000 Coin Recycler Chassis counterclockwise at approximately turn to secure the Validator Module in place The scre...

Страница 10: ...available devices Note The NCR FastLane SelfServ TM Checkout application automatically runs and installs all available devices If the new or replaced device is not listed in the ADD CADD window an err...

Страница 11: ...8...