5-2
Chapter 5: Touch Screen Calibration - Windows
4-Point Calibration Procedure
Note:
The
9-Point Linearization
procedure should be performed first if either the Touch
Screen Sensor or the Controller Board is replaced.
1.
From the Windows Start button, select
Settings
→
Programs
→
TouchKit
→
Configure Utility
2.
From the
TouchKit:USB Controller
screen, select the
Tools
tab.