nCounters Essential Angle Sensor Unit Скачать руководство пользователя страница 4

Care of the Control Unit 

 

Installing the battery 

 

 

Remove  the  back  panel  of  the  enclosure  and 
insert the battery with the plus (+) and minus (-) 
poles pointing in the designated direction

 

Use  one  9  Volt  (PP3)  battery.  A  rechargeable 
9V battery maybe used. 

 

Remove the battery if the control unit will not be 
used for a month or longer. 

 

If  the  battery  is  incorrectly  replaced,  the  control 
unit will not function. 

 

In the event of battery leakage, wipe the control 
unit completely clean and install a new battery. 

 

Cleaning 

 

 

All surfaces of this system are non-porous and 
should be cleaned between each client, using a 
disinfectant wipe 

 
 

Operating the control unit 

 

 

What’s what?

 

 

 
 

 

 

Figure 1 

Control Unit Front Panel  

 

NB THERE IS NO AUDIO FEEDBACK 
WHEN CLIENT IS IN THE TARGET RANGE 

 

Page 3

 

 

1.

 

ON / OFF switch 

 

2.

 

UPPER LIMIT 

Dial to be used by therapist to establish upper 
limit of target range 

 

3.

 

OUTPUT for DataQ Unit 

Socket for plug of red cable to transfer data 
from control unit to DataQ Unit (

Figure 2) 

See Accessories for DataQ

 

 

 

Figure 2 

DataQ Output Socket 

 

4.

 

Headphone Socket (Mono) 

 

5.

 

Volume Control 

For either speaker or headphone  

NB Audio feedback by either speaker or headphone 

 

6.

 

Low Battery LED 

Battery needs to be 

immediately

 replaced or 

recharged when LED comes “on”

 

 

7.

 

Speaker 

 

8.

 

10 LED BAR DISPLAY 

Real  time  visual  feedback  is  provided  by  a  10 
coloured LED display. 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.  INPUT socket 

For Angle Sensor plug 

 

10

.

 

LOWER LIMIT 

 

Dial to be used by therapist to establish lower 
limit of target range 

 

RED

 

LED

 bars 

represent 

LOWER

 

values 

 

GREEN

 

LED

 bars 

represent 

HIGHER 

values 

10 

DataQ 
socket 

Содержание Essential Angle Sensor Unit

Страница 1: ...______________________________________________ Operation Manual Essential Angle Sensor Unit REV C DataQ Unit October 2019 _____________________________________________________________________ Please u...

Страница 2: ......

Страница 3: ...is for commercial use only Indications and Intended Use Designed to give immediate audio and visual feedback on hip knee and elbow joint movement the Essential Angle Sensor can be used to facilitate f...

Страница 4: ...NB THERE IS NO AUDIO FEEDBACK WHEN CLIENT IS IN THE TARGET RANGE Page 3 1 ON OFF switch 2 UPPER LIMIT Dial to be used by therapist to establish upper limit of target range 3 OUTPUT for DataQ Unit Sock...

Страница 5: ...will hear no sound If the joint angle is outside these two limits then the client will receive audio feedback via the speaker or headphone The sound changes and increases in pitch the further away the...

Страница 6: ...ocket 4 and adjust volume until it is comfortable for the client Set Target Range Position sensor at angle where feedback is required The therapist needs to set the correct upper and lower limits Make...

Страница 7: ...steps For installing DataQ software on your PC Go to https www dataq com products di 1100 Click on software tab Download WinDaq Software Then click Download now button A DataQ exe file will be downloa...

Страница 8: ...will find application file WINDAQ Waveform Browser Double click to activate the browser You will use this software to look at your recorded files Choose one then scroll along the bottom of the screen...

Страница 9: ...Page 8 SIZE GUIDE FOR ANGLE SENSOR STRAPS XSMALL XS 15 20cm elbow knee SMALL S 22 30cm elbow knee MEDIUM M 40 55cm knee hip LARGE L 45 75cm knee hip XLARGE XL 55 95cm knee hip XXLARGE XXL 75 120cm hip...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Отзывы: