background image

Model 6700 Family User’s Manual

26

Display shows unrecognized characters

1.

Check software PROM for proper insertion.

2.

Check display cables for the proper connec-
tion.

3.

Replace PROM.

4.

Replace the display board.

5.

Replace the main board.

Display shows under “_ _ _ _” dashes

(Indicates that the scale is below zero or under
capacity.)

1.

Verify that weigh platter is on the scale.

2.

Press the 

ZERO 

key.

3.

Power down, remove any items from the
platter, and then power up the scale.

4.

Recalibrate the scale.

5.

Replace the load cell.

6.

Replace the main board.

Display shows center“_ _ _ _” dashes

(Indicates that the scale is outside zero capacity
of ±2%.)

1.

Verify that weigh platter is on the scale.

2.

Press the 

ZERO 

key.

3.

Power down, remove any items from the
platter, and then power up the scale.

4.

Recalibrate the scale.

5.

Replace the load cell.

6.

Replace the main board.

Display shows upper” _ _ _ _ “ dashes

(Indicates the scale is over capacity.)

1.

Remove all items from the scale.

2.

Press the 

ZERO 

key.

3.

Power down, and then power up the scale.

4.

Recalibrate the scale.

5.

Replace the load cell.

6.

Replace the main board.

Содержание 6720

Страница 1: ...User s Manual Model 6700 Family Model 6720 Model 6702 Model 6710 Point of Sale Interface Scales...

Страница 2: ...ectrical shock Do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel Weigh Tronix reserves the right to change specifications at any time CAUTION 03 12 02...

Страница 3: ...ications 4 Initial Setup 7 Operation 8 Menu Structure 11 Diagnostics Mode 13 Configuration Mode 17 Calibration Mode 19 Review Test Scale Settings 21 Communication 22 Error Codes 24 Troubleshooting 25...

Страница 4: ...ant Weights and Measures normally requires inspection of scale before scale is placed into operation Model Capacity lb Capacity kg 6702 7 15 x 005 7 x 002 6702 15 30 x 01 15 x 005 6710 7 15 x 005 7 x...

Страница 5: ...load protection Adjustable center and side stops Model 6720 Die cast aluminum base with a stainless steel weigh platter Overload protection Adjustable center stop fixed corner stops high six digit LCD...

Страница 6: ...a lead wire or pressure sensitive security seal The remote or primary indicators have no metrological features that require the use of a security seal The scale has 100 000 internal counts The time i...

Страница 7: ...use the dimensions on the following page to guide construction Scale Dimensions Min Cut Out Dimensions D 10 4 in 26 4 cm 11 1 in 28 2 cm W 6 4 in 16 3 cm 7 1 in 18 0 cm H 2 5 in 6 35 cm Adjustable to...

Страница 8: ...cale can support more than one display however only one keypad is oper able Switch 3 selects internal or external display keypad operation Switch 3 Settings Closed internal display keys operational Op...

Страница 9: ...The TEST key can be used to perform the initial power up test sequence recall diagnostic routines or to view the scale configu ration information This key also acts as YES or ACCEPT in the Menu mode T...

Страница 10: ...the scale s function CAL Calibration Mode To calibrate the scale CONF Configuration Mode To configure the scale for your application The structure for these menus is shown in Figure 3 Specific informa...

Страница 11: ...Model 6700 Family User s Manual 11 Figure 3 Menu Structure...

Страница 12: ...acity Alternative Capacity Calibration Weights 9 995 lb 10 lb 15 x 005 lb 10 15 lb 7 x 002 kg 7 kg 9 995 kg 10 kg 30 x 01 lb 10 20 30 lb 15 x 005 kg 10 15 kg 60 x 02 lb 10 30 60 lb 30 x 01 kg 10 20 30...

Страница 13: ...back into the receive channel and verified against what was sent Requires a jumper short between transmit and receive data lines DIVISION TEST w AZT DIV A Weight data is normalized to 100 000 counts...

Страница 14: ...1 or 2 DIAG is displayed 2 Press the TEST key DISP is displayed This stands for display 3 Press the TEST key to perform the display test described earlier Display test is performed and the display sho...

Страница 15: ...his stands for the high resolution DIVISION TEST w o AZT enabled 14 Press the TEST key to perform this test The display shows the weight on the scale at a resolution of 100 000 counts 15 Press the TES...

Страница 16: ...col selection is displayed 20 Press the ZERO key BAUD is displayed This stands for baud rate 21 Press the TEST key The current baud rate and parity selec tion is displayed 22 Press the ZERO key CAP is...

Страница 17: ...standard ECR Cash register compatible 8213 8213 compatible Sharp 2250 2250 compatible Swintec 34 F 34 MF compatible Sweda Mexico ATT AT T compatible o4000 Olympia Cash Register compatible Access the M...

Страница 18: ...splayed 6 Press the TEST key The current baud and parity choice is displayed 7 Use the ZERO key to scroll the choices found in Table 2 When the choice you want is displayed press the TEST key The choi...

Страница 19: ...e normal weighing mode move Switch 1 to the Menu mode or OPEN position Press the ZERO key until CAL is displayed 2 Press the TEST key 50 H or 60 H is displayed This is the AC line frequency 3 Press th...

Страница 20: ...weights on the scale and press the TEST key After a brief wait DONE is displayed 8 Remove all calibration weights from scale 9 Press the TEST key DIAG is displayed or return Switch 1 to the closed po...

Страница 21: ...iew the current system settings press and hold the TEST until the display shows dashes _ _ _ _ Release the TEST key and the display will prompt DISP and the scale is now in the Review Test Mode Press...

Страница 22: ...RS 232 communication only Serial commands will be responded to only when the scale is in the normal operating mode and Switch 1 on the main board is in the CLOSED position Baud Rates 1200 2400 4800 96...

Страница 23: ...al list for the DA 15 pin interface cable Pin RS 232 4 Bit Parallel 1 RXD Data 1 2 TXD Data 2 3 Sig Gnd Sig Gnd 4 Data 4 Data 4 5 Data 8 Data 8 6 DSR Over Capacity 7 DTR NC 8 BHZ BHZ 9 In Motion In Mo...

Страница 24: ...4 JMP 1 4 DTR OUT 5 SG 5 GRD 6 JMP 1 6 DSR IN 7 JMP 2 7 RTS OUT 8 JMP 2 8 CTS IN 9 NC 9 RI IN Any system errors detected by the scale will be displayed as the letter E followed by a two digit error c...

Страница 25: ...oard 4 Replace the main board Missing or extra segments on display 1 Replace the display board 2 Replace the main board Scale will not return to zero or incorrect weight is displayed 1 Press the ZERO...

Страница 26: ...then power up the scale 4 Recalibrate the scale 5 Replace the load cell 6 Replace the main board Display shows center _ _ _ _ dashes Indicates that the scale is outside zero capacity of 2 1 Verify tha...

Страница 27: ...PCB 4 Replace the display cable 5 Replace the main PCB DESCRIPTION PART NUMBER Keyboard Panel 1163 13205 Display PCB 7405 15465 RS 232 PCB 7405 14704 2 4 Bit Parallel PCB 7405 14653 2 40 Bit Serial P...

Страница 28: ...Model 6700 Family User s Manual 28 Notes...

Страница 29: ...Model 6700 Family User s Manual 29...

Страница 30: ...Model 6700 Family User s Manual 30...

Страница 31: ...Model 6700 Family User s Manual 31...

Страница 32: ...1000 Armstrong Drive Fairmont MN 56031 Telephone 507 238 4461 Facsimile 507 238 4195 E Mail service wt nci com www wt nci com...

Отзывы: