background image

Working time period setting

 

 

Work time period setting

 

There  are  5  operating  times  available  to  be  set  every  day 

(Figure 3).

 

Press SET button to set the 1st working period (ON1). Press ▲ 

or ▼ to select the desired working period (1-5). Press ENT for 

the working period switch, touch ▲ or ▼ to choose ON or OFF, 

press ENT button again to move to the operation time, press ▲ 

or ▼ to adjust number.

 

Press ENT again to set the scent level. Then press ENT to select 

the day (MON). Press ▲ to set the working period (ON1) (see 

Figure 4) or press ▼ to select the end time (OFF1) (see Figure 

5). Press ENT to go to the next day and repeat the above steps 

for TUES to SUN.

 

When you are fi 

press SET to confi     the setting and exit,

 

or press ENT set additional operating times (ON 1).

 

Repeat the setting steps for working times ON2, ON3, ON4 and 

ON5.

 

P.S.: Device will not work if the start and end times are identical.

 

 

Working 

00:00

 

time period    

00:00

 

00:00

 

00:00

 

00:00

 

00:00

 

00:00

 

00:00

 

00:00

 

00:00

 

Mon

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

Tues

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

Wed

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

Thur

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

Fri

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

Sat

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

Sun

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

ON/OFF

 

 

 

12 

Important Note:

 

The fi     working period is preset to start at 07:00 a.m. and 

end to 7:00 p.m. with fragrance level 1,

 

All other working period times are set to 00:00.

 

Содержание Mystic Air 950

Страница 1: ...Mystic Air 950 BT Touch Manual www ncheurope com...

Страница 2: ...Time Setting 11 8 Working Time Period Setting 12 9 Caution 13 10 Warning 14 11 Troubleshooting 14 12 Equipment Cleaning 15 Hereby NCH Europe declares that the Mystic Air 950 radio system is in complia...

Страница 3: ...ght 3 65kg Coverage 2000m2 5000m3 Power 30W Voltage AC220V Atomized head PU tube Manual Atomized connector Bottle if ordered Screws Handle 3 Please check and make sure all accessories are included aft...

Страница 4: ...ation Control Panel Atomized connector Air inlet Switch Application Hotels meeting rooms malls exhibition halls brand retail stores bars SPAs businessplacesandwhereveryouwanttoenjoyapleasantscentexper...

Страница 5: ...Installation Installation steps of the bottle Screw the connector on the atomized head Screw the atomized head on the scent bottle connector HVAC connection 5...

Страница 6: ...Instructions Air Flow Air Duct Scent point Air Tube Max length 3m Scented air flow Max length 3m Ceiling Interior space Mystic Air Installation step 6...

Страница 7: ...u may enter the Device control area to set your Mystic Air 3 7 IMPORTANT NOTE Make sure Bluetooth is activated on your smartphone If your AromaStreamer does not immediately connect to the App please p...

Страница 8: ...ce further information 4 5 Sample Setting By pressing the button you can define up to 5 different scent settings Set different days or switch off the device during the lunch break Through various sett...

Страница 9: ...to 20 Save Confirm your settings at the top right with Save and you will return to the Device control By using the buttons on the right side you can switch flexibly the times into active and inactive...

Страница 10: ...new password twice Finally confirm your input with Save to return to the menu 8 8 If you do not want to make any further adjustments or changes to your Mystic Air you can close the App Now the device...

Страница 11: ...settings are made within 60s Press SET approx 5s until you hear a beep The screen is now unlocked Local time setting Press the SET button for about 5 seconds until you hear a beep The date display st...

Страница 12: ...at the above steps for TUES to SUN When you are fi press SET to confi the setting and exit or press ENT set additional operating times ON 1 Repeat the setting steps for working times ON2 ON3 ON4 and O...

Страница 13: ...and lightening Shall not disassemble the machine when it is under operating Warning 1 After installation please keep the machine vertical Tilting or placing it flat may cause an oil overflow and Mysti...

Страница 14: ...or not Check if the machine is during Non Working period Check whether the tube is loose or not Oil leaking Check whether the bottle is loose or not The gasket in the atomized head is damaged or loose...

Страница 15: ...o the nebulization unit Now run your Mystic Air for about 15 minutes on the highest intensity level 3 You can use the device directly after cleaning Shipping Return 1 Please always use the original bo...

Страница 16: ...NCH Distribution s r o Si ejovick 1213 410 02 Lovisce Czech Republic Tel 420 416 429 111 https campaigns ncheurope com facilities mystic air...

Отзывы: