NCE Switch-It Скачать руководство пользователя страница 3

Programming information

   

The Switch-It 

cannot 

be programmed on your programming track. It is always

programmed while connected to the mainline track.  This decoder can be programmed
by all systems that support accessory control using the procedure below.  

To program switch "A" to a new address using any DCC system:

1) Connect wires from the track to the decoder 

TRK

 connections.

2) Connect a short "jumper" wire from the 

PA

 terminal to common as shown below.

3) Use your DCC system to throw the accessory (switch) number you want the

Switch-It to use as its 

new

 address. 

To throw a switch using the NCE or MRC system:

Press “SEL ACCY”
Type in the accessory number followed by “ENTER”
Push “1” to throw the switch.

To throw a switch using a Digitrax system:

Press “SWCH”
Type in the accessory number
Push “OPTN” to throw the switch.

To throw a switch using a Lenz system:

Press “F”
Press “5”
Type in the accessory number followed by “ENTER”
Push “+”

4) Remove the jumper wire. 

Do 

not

 leave the jumper in place after programming or you won’t be able to

control the switch.

 

To program switch "B" to a new address using any DCC system:

1) Connect wires from the track to the decoder 

TRK

 connections.

2) Connect a short "jumper" wire from the 

PB

 terminal to common as shown below.

3) Use your DCC system to control the accessory (switch) number you wish the

decoder to use as its address for the 

SWB

 output. (see step 3 above)

4) Remove the jumper wire.

Do 

not

 leave the jumper in place after programming or you will not be able to

control the switch.

            Last revised:  15 March 2007                                                                              Page3

"Jumper" wire

to program SWA

TO TRACK

"Jumper" wire

to program SWB

Install only ONE jumper at a time when programming accessory addresses

TRK

SWA

S

WB

1

2

3

4

NCE SWITCH-IT  REV C

RST

PA

PB

Содержание Switch-It

Страница 1: ...esses 1 2044 Easy address programming no need to connect it to programming track Each switch machine can have its own completely different address Simple hook up 2 wires to the track 2 wires to each switch machine Includes optional connections for local control push buttons Also operates on non DCC layouts Every attempt has been made to ensure this decoder complies with all applicable NMRA Standar...

Страница 2: ... parallel for operation of the machine from more than one control panel If the Switch It is used on DC 12 16 volts DC the buttons will still work You can also program the Switch It to toggle the outputs with each push of the local control pushbuttons Button 1 will control the SWA output and button 4 will control the SWB output Buttons 2 and 3 will be ignored and are not needed Switch machine mount...

Страница 3: ... the accessory number Push OPTN to throw the switch To throw a switch using a Lenz system Press F Press 5 Type in the accessory number followed by ENTER Push 4 Remove the jumper wire Do not leave the jumper in place after programming or you won t be able to control the switch To program switch B to a new address using any DCC system 1 Connect wires from the track to the decoder TRK connections 2 C...

Страница 4: ... CV547 0 to disable it If you have another brand of DCC system consult your manual for programming of accessories in Operations mode Legacy OPS programming disable CV554 There are two methods for programming accessory decoders on the main OPS mode programming Legacy mode in use since 1995 is being phased out by the NMRA and replaced by the current newer method The Switch It supports both kinds of ...

Страница 5: ...r output when used in a crossover We can t guarantee this will work in all cases vThe outputs of the decoder are always on to prevent the switch machine from backing off due to the springiness of the turnout throw mechanism vIf CV547 is programmed to 1 exercise enabled the decoder will back off the switch usually about halfway then return the switch to its remembered position at power up This is t...

Страница 6: ...r loads beyond the design range of the decoder or short circuits in the locomotive manufacturer s factory wiring The warranty is voided if the decoder is miswired connected to more than 22 volts or used with switch motors drawing more than 40mA If the decoder fails for non warranted reasons NCE will replace the decoder no questions asked for 10 US plus 2 shipping For warranty or non warranty repla...

Отзывы: