CV135-CV146 -

 

Custom Startup Table

 (Note: this if for the technically inclined)

The custom startup table provides a programmable method to pulse the track power on and
off several times before the AR10 tests for over current. You can program the on and off
times in increments of 1mS.  Generally you will not use this table with most boosters but it
may be useful with a booster that has weak startup capability. 

An "off" time of 0 indicates the last entry of table. With the factory default of CV144 = 0
indicates the AR10 will not try to use the 6th "on" time.

If CV135 = 0 the table is disabled. 

CV135 default = 0 Custom startup table initial "on" time 
CV136 default = 4 Custom startup table initial "off" time
CV137 default = 8 Custom startup table 2nd "on" time
CV138 default = 4 Custom startup table 2nd "off" time
CV139 default = 16 Custom startup table 3rd "on" time
CV140 default = 4 Custom startup table 3rd "off" time
CV141 default = 32 Custom startup table 4th "on" time
CV142 default = 4 Custom startup table 4th "off" time
CV143 default = 80 Custom startup table 5th "on" time
CV144 default = 0 Custom startup table 5th "off" time
CV145 default = 0 Custom startup table 6th "on" time
CV146 default = 0 Custom startup table 6th "off" time

CV147 Factory reset 
This will reset the AR10 to its original factory settings

Set CV147 = 85 to do a factory reset of the AR10 to the following values. 

CV129 default = 1       16mS allowable short circuit
CV130 default = 128   2 seconds power off time
CV131 default = 0       Manual reset off
CV135 default = 0       Custom startup table disabled
CV136 default = 4 
CV137 default = 8 
CV138 default = 4 
CV139 default = 16 
CV140 default = 4 
CV141 default = 32 
CV142 default = 4 
CV143 default = 80 
CV144 default = 0 
CV145 default = 0 
CV146 default = 0
CV148 default = 204 (8 Amps) 

**Last revised:  3 May 2020

Page 6

AR10

Содержание AR10

Страница 1: ...screw terminals no soldering Solid state design provides silent reliable operation Status indication LED Additional output for remote LED Automatic or manual reset after short circuit shutdown Adjust...

Страница 2: ...g a short dead section the length of the longest metal truck in the train This will be required at both the entrance and exit of the loop The terminal strips on the AR10 accept up to 12 AWG wire We re...

Страница 3: ...desired position The diagram below shows the settings Testing the installation After setting the trip current we recommend testing your wiring The quarter test is the fastest way to test your wiring U...

Страница 4: ...at set the current trip level See page 3 for a description Connections to the AR10 MAIN TRACK DCC power input from the DCC booster LOOP DCC track power output terminal from the AR10 to the loop track...

Страница 5: ...program CVs when using PROGRAM ACCESSORIES ON THE MAIN mode with an NCE system Fine Tuning the AR10 CV129 Adjustment of short circuit response time if necessary You can adjust the time delay between...

Страница 6: ...e 2nd off time CV139 default 16 Custom startup table 3rd on time CV140 default 4 Custom startup table 3rd off time CV141 default 32 Custom startup table 4th on time CV142 default 4 Custom startup tabl...

Страница 7: ...Intentionally blank page Last revised 3 May 2020 Page 7 AR10...

Страница 8: ...inst manufacturing defects for a period of 1 year As the circumstances under which it is installed can not be controlled failure of the device due to installation problems can not be warranted This in...

Отзывы: