background image

3

PARTS LIST

ITEM 

NO.

PART NAME

DRG NUMBER

Size (inch)

IMAGE

QTY.

1

S1C Frame

S1C

78.74 x 40.74

8

2

JF1 Bracket

JF1

4.33 x 1.57

9

3

CB1 Bracket

CB1

4.3 x 4.3 x 

1.57

9

4

ST3 Roof Tie

ST3

81.1 x 1.57 x 

1.57

1

5

FT3 Bracket

FT3

1.57 x 3.15 x 

4.17

7

6

FT1 Bracket

FT1

1.57 x 1.57 x 

3.94

2

7

DR Bracket

DR

4.3 x 1.6 x 2

16

8

AR1R  1m Pitch Rafter

AR1R

45 x 11.8 OA

5

9

Roof F Section Outer

ARFSO

41.5

4

10

ARFSI  Apex Roof F 

Section Inner

ARFSI

40.75

4

11

AR1CLTO  1m Apex 

Roof Centre Lower 

Trim Outer

AR1CLTO

41.4

2

12

AR1CUTO  1m Apex 

Roof centre upper trim 

outer

AR1CUTO

41.5

2

13

AR1IS  1m Pitch Infill 

Panel Shallow

AR1IS

45.2 x 13.5

2

14

AR1POA  Roof Panel 

outer alu

AR1POA

41.5 x 24.4

4

15

AR1PIA  Roof Panel 

inner ALU

AR1PIA

40.75 x 24.4

4

16

AR1TS  1m Apex Roof 

Trim strips

AR1TS

24.8 x 2.3

6

17

AR1CLTI  1m Apex 

Roof centre lower trim 

inner

AR1CLTI

40.74

2

18

AR1CUTI  1m Apex 

Roof centre upper trim 

inner

AR1CUTI

40.75

2

19

40x40 End cap

EC40

1.57 x 1.57

2

Содержание SR8061-F

Страница 1: ...Assembly Instructions Shelter type SR8061 F SR8061 F 02 29102021 USA...

Страница 2: ...14 15 14 12 17 11 13 13 6 1 3 4 18 10 7 1 8 5 16 9 2 19 19 2 3 2 Overall Shelter sizes...

Страница 3: ...Outer ARFSO 41 5 4 10 ARFSI Apex Roof F Section Inner ARFSI 40 75 4 11 AR1CLTO 1m Apex Roof Centre Lower Trim Outer AR1CLTO 41 4 2 12 AR1CUTO 1m Apex Roof centre upper trim outer AR1CUTO 41 5 2 13 AR1...

Страница 4: ...4 FIXINGS...

Страница 5: ...K CORRECT ALIGNMENT Please note 1 5 Tec Screws are for roof panels only S1C CB1 CB1 JF1 JF1 ENSURE CORRECT ALIGNMENT ON CORNERS JF1 JF1 CB1 Step 1 Assemble S1C frames to make up the main structure usi...

Страница 6: ...JF1 ST3 CB1 CB1 CB1 Step 2 Use JF1 and CB1 brackets to attach the S1C frame and ST3 Tie bar 6...

Страница 7: ...75 40 75 40 75 ENSURE CORRECT ALIGNMENT OF RAFTERS AND S1C FRAMES Step 3 Attach AR1R rafters using DR brackets Secure the AR1IS END PANELS to S1C frames using tec screws The end rafters need to be pl...

Страница 8: ...ARFSO ARFSO ARFSI ARSCLTO ARFSI DETAIL A SCALE 1 2 8 Attach the AR1CLTO and AR1CLTI to the top of the rafters The AR1CLTO are to be lined up near the end panels and the AR1CLTI have to be spaced equal...

Страница 9: ...9 Step 5 Attach the AR1POA roof panels on the outer edges of the shelter nearest to the end panels and the AR1PIA pannels need to be equaly spaced along the centre Cap off the top using AR1CUTO and A...

Страница 10: ...164 88 42 34 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base 8 oversized on all 4 sides...

Страница 11: ...anels regularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales nobutts com Web www nobutts...

Отзывы: