background image

 

 

 

At the stage of correctness verification of the connection and settings of the device, it is not recommended to include 

actuators in the relay circuit directly. It is advisable to do this at the final stage of testing. 

30

85

86

87a

87

14

7

13

6

12

5

11

4

10

3

9

8

2

1

Fuse

(1A)

«GND»

«+»

«-»

Car battery

Diode 1N4007

Fuse

External

device

+

-

«GND»

 

 

Figure 33. Connection diagram of the relay to the outputs of the device OUT1 and OUT2 

 

 

2.7 1-Wire informational interface (IButton) connection 

 

 1-Wire controller interface (IButton) allows to connect up to four digital sensors like DS18S20 (DS18B20) to the 

device, and it can also operate with DS1990 keys or key / card readers that emulate DS1990 keys via interface 1- Wire. 

Each DS1990 key is a chip with a unique identification number stitched into it at the manufacturing plant by which 

the device identifies this sensor. 

Saving the key codes in the device’s memory allows to use identification when changing the security mode, activating 

the output with the profile set: “TM registered key indicator” and “TM key indicator”, and also necessary for operation of 

the “Immobilizer” function. 

The maximum number of stored keys - 510. 
It is also allowed to connect external readers of contactless Proximity-cards and keyfobs that have TouchMemory 

DS1990A  key  emulation  interface.  However,  such  readers,  as  a  rule,  do  not  operate  together  with  thermal  sensors 

connected to the same physical interface. 

 

 

Figure 34. TouchMemory System Key 

 

 

Figure 35. TouchMemory key contact reader 

 

 

Figure 36. Temperature sensor based on DS18S20 chip 

 

Содержание SMART S-2433

Страница 1: ...GPS GLONASS TRACKING EQUIPMENT SMART S 2433 Operations manual Installation and connection of the device v1 0 MOSCOW 2020...

Страница 2: ...terested in constantly improvement of the manufactured products quality Please contact our technical support by email address support navtelecom ru should you have any questions or problems with the d...

Страница 3: ...11 2 DEVICE CONNECTON 12 2 1 Installation 12 2 2 SIM card installation and operation 13 2 3 Power connection 13 2 4 Universal inputs connection 14 2 4 1 Analog sensors connection 14 2 4 2 Discrete se...

Страница 4: ...de control of cargo safety by comprehensive measures improving driver and passenger s safety 1 3 Operational principles The device during its operation continuously monitors the status of the connecte...

Страница 5: ...t consumption at 12 V voltage in operation mode on average3 mA 80 Current consumption at 12 V voltage with turned off GLONASS and GSM modules is no more than mA 25 Maximum current consumption at 12 V...

Страница 6: ...090 1 Optional 2 If maximum operating voltage is exceeded the power protection is activated The device continues to work but is powered by the battery 3 If GPRS operates in poor communications peak co...

Страница 7: ...iniUSB connector for connection with a computer SIM card holder slot with ejector yellow button In the upper part of the device unit Figure 3 there are three indicators system indicator SYS modem oper...

Страница 8: ...ce cable with MiniUSB connector 1 5 Passport 1 6 Package 1 Figure 4 14 pin connector of Microfit 14 Figure 5 Interface cable with MiniUSB connector Some cases may require connection of additional equi...

Страница 9: ...Figure 9 External LED Figure 10 Temperature sensor Figure 11 TouchMemory contact key reader The manufacturer reserves the right to complete the devices with equipment whose set appearance and characte...

Страница 10: ...e 12 15 1 front cover 2 fixing hole 3 system LED indicator 4 GSM LED indicator 5 GLONASS GPS LED indicator 6 14 pin connector 7 MiniUSB connector 8 SIM card 1 ejector holder 9 SIM card holder 1 extern...

Страница 11: ...Figure 14 Figure 15...

Страница 12: ...is prohibited to apply a voltage more than 50 V to the device universal inputs because it may lead to the failure of the device Outputs OUT1 and OUT2 open collector type are designed to control low cu...

Страница 13: ...erature more than 60 C for example near heating systems etc It is also prohibited to place the device in a sealed container without heat dissipation It is prohibited to install tracker in places with...

Страница 14: ...o the power supply through a 1 A fuse not included in standard equipment set During installation the power supply should be connected the last turn when all the other equipment is already connected Co...

Страница 15: ...Analog sensor s connection 2 4 2 Discrete sensors connection The device allows to connect any type of sensors that have two steady states on activated and off normal The voltage thresholds at which t...

Страница 16: ...c R1 R2 UIN C1 CPU_pull up VDD Figure 22 Connection of normally closed NC sensors Profiles Discrete NC and Discrete NO allow to work with sensors which when turned on or off close the input to supply...

Страница 17: ...be used as an ignition 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse 1 U Ignition switch UIN1 Alarm button GND GND Car battery Figure 25 Connection of the ignition lock and alarm button Digital inputs are co...

Страница 18: ...2 5 Built in accelerometer There are virtual sensors based on the built in accelerometer three axis acceleration sensor soft and strong impact sensors displacement sensor and tilt sensor in the devic...

Страница 19: ...d Buzzer without built in generator can be connected only to OUT1 because only this line has opportunity to modulate the control signal for the buzzer Buzzer with built in generator can be connected t...

Страница 20: ...Designation of the external relay contacts When voltage is applied to control contacts relay is activated and closes or opens the electrical circuit with power contacts Power contacts are always marke...

Страница 21: ...90 keys via interface 1 Wire Each DS1990 key is a chip with a unique identification number stitched into it at the manufacturing plant by which the device identifies this sensor Saving the key codes i...

Страница 22: ...d of the bus that is opposite to the connected device it should be closed by the last plug in sensor 14 7 13 6 12 5 11 4 10 3 9 8 2 1 Fuse 1A GND Car battery Temperature sensors DS1820 Data Data Data...

Страница 23: ...ed to reconnect them by swapping the RX and TX contacts If there is any doubt which sensor line is Tx and which Rx it is possible check this with a multimeter in the voltage measurement mode The measu...

Страница 24: ...A RS485 Line B FLS Line A RS485 Line B Figure 40 Connection diagram of fuel level sensors by RS 485 interface In the fuel sensor the periodic data output mode must be turned off and the network addre...

Страница 25: ...cond off There is a registration in the cellular network of the operator Weak signal 2 short flashes 1 second off There is a registration in the cellular network of the operator Medium quality signal...

Отзывы: