09
08
Note
:
During the recover input entering process, if there is an input error need to be re-entered, you only
need to press the shift button , move the flashing figure to the position of the figure to be
corrected, re-enter the correct figure to complete the correction of the recover weight.
Firstly charging default is 0 after hand held start-up, and press again “recover” will be displayed the
measurement of the last recovery.
Warning
:
The recovered refrigerant volume cannot exceed 80% of the total capacity of the refrigerant
container. This is extremely dangerous.
4.2.7 Bluetooth Synchronization Setup
If the handhold device or weight pan needs to be changed, it is needed to synchronize the
bluetooth,as follows,
1. First, short press Power key to start the weighing pan. The blue light for Bluetooth
indicator on the weighing scale starts flashing and wait for pairing;
2. When the handhold device is at off state,press
,
,
,
,
in sequence, then the
handhold device enters sync program, the LCD shows , the alarm buzzes. The sync will be
done within 1 minutes, the LCD shows , the alarm buzzes for 2 seconds. Conserve the new
MAC address, the handhold device turns off automatically.
Note
:
if the sync is not done within 1 minutes, the handhold device is out of sync program. Keep the
previous MAC address, and the handhold device turns off automatically.
4.2.8 Calibration
V. Maintenance
1) Only use a moist cloth and a small amount of cleaning fluid when cleaning the surface of the
e-scale, and make sure to avoid using chemical solvents to wipe the product.
2)If repair is required, contact a NAVTEK dealer company. Once the device is opened by an
individual or non-authorized company, we will no longer provide warranty.
3)After finishing usage, promptly turn off the e-scale. When left idle for long-periods, promptly
remove the battery.
4)Do not store the e-scale in moist, high-temperature or magnetized locations.
VI: Attached list
1)E-scale (scale plate and hand held device)
2)User manual
3)1.5V‘AA’alkaline battery
4)1.5V‘AAA’ alkaline battery
1 set
1
4
4
When the weighing pan is at off state, press first, and then . At this moment, Low-Battery
red light is on. Keep the two buttons pressed for 10 seconds, till the Bluetooth blue light is on.
Loose the
, then Low-Battery red light is off. Keep pressing the for over 5 minutes, till the
Low-Battery red light and Bluetooth blue light flashes alternately. Loose the
, then the Low-
Battery and Bluetooth is on to start the calibration program.
Within 10 seconds, press , to represent NRS3i01. Then Low-Battery red light and Bluetooth
blue light flashes fastly. Keep the scale is unloaded. When the Low-Battery red light and
Bluetooth blue light flash 1 second simutaneously, Place 176.4lbs standard weight on
NRS3i01,
waiting for the automatic calibration. If the calibration succeeds, the Bluetooth blue light is on for
10 seconds, and the scale turns off automatically. If the calibration fails, the Low-Battery red light
is on for 10 seconds, and the scale turns off automatically.
1.
2.
Note
:1. after calibration, press 2 seconds, to turn off scale manually.
2.When the correction is unconditionally, please return it to the company
or the authorized
retailer for correction.
Correct Disposal of this product
This marking indicates that this product should not be disposed with other household
wastes throughout the EU. To prevent possible harm to the environment or human health
from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of
material resources. To return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this product for
environmental safe recycling
.
Note
:
Confirm the models are NRS3i01 before calibration, the weighing range is 60kg, or, 120kg. Make
sure the battery power is enough to assure accuracy for calibration. If the battery power is low,
Low-Battery red light flashes 10 seconds fastly and then turns off automatically, and the calibration
fails.
Lb
oz
5. When the recovered weight reaches the pre-set recovery weight, recovery is completed, and
you can manually end system recovery by pressing , and the alarm will stop. At this point
the LCD screen will display the gross weight of the refrigerant container.