NAVMAN R100 User Manual
Wiring Connection
• Keep electrical and transducer cables away
from alternator or other noise generating
electrical cables. Avoid connecting the
instrument to power circuits that share
loads with ignition, alternators, inverters and
radio transmitters. Electrical power supply
connections should always be as short as
possible.
• Connect the red wire to the positive supply
via a 1 amp fuse or a 1 amp circuit breaker.
Connect the black wire to the electrical
ground. A 1 amp fuse will provide protection
for up to five 100 series instruments.
• The NAVMAN R100 repeater is intended to
be connected with a number of other 100
series instruments or to other instruments
that output NMEA 0183 data.
1A Fuse
+12 VDC
White
White
Yellow
Yellow
Blue
Blue
Green
Black
Black
Red
Red
Green
Ground
Connecting Multiple Repeaters
Multiple repeaters may be connected so that
repeaters can be placed in different locations or
to allow the simultaneous display of a greater
number of functions.
Yellow
NMEA Input
Black
Ground
Blue
NMEA Input
Green
NMEA Input
White
NMEA Input
Red
+12 VDC