![Navman G-PILOT 3380 Скачать руководство пользователя страница 28](http://html2.mh-extra.com/html/navman/g-pilot-3380/g-pilot-3380_installation-manual_3606871028.webp)
G-PILOT 3380 System Installation Manual
NAVMAN
29
Electrical:
Supply voltage:
10.5 to 30.5 V DC.
Supply current ( at 13.8 V):
Without backlighting: 160 mA.
With full backlighting: up to 410 mA.
Other optional instruments: refer to the
instrument’s operation manual.
Interfaces
NavBus:
connection to MCU and other Navman
instruments.
AP3380 Display unit power/data cable wires:
Black connector - Power and MCU
Pin
Wire color
Signal
5
Red
Power positive, 10.5 to 30.5 V DC
1
Black
Power negative
6
Orange
4
Blue
NavBus -
7
Yellow
Ignition wire
3
White
Factory use (isolate, do not cut)
8
Green
External alarm, switched to ground, 30 V DC and 250 mA max.
2
Brown
Factory use (isolate, do not cut)
Green connector - NavBus expansion
Pin
Wire color
Signal
5
Red
Factory use (isolate, do not cut)
1
Black
Power negative
6
Orange
4
Blue
NavBus -
7
Yellow
Factory use (isolate, do not cut)
3
White
Factory use (isolate, do not cut)
8
Green
Factory use (isolate, do not cut)
2
Brown
+9V out
Standards compliance:
EMC compliance:
USA (FCC): Part 15 Class B
Europe (CE): IEC 60945:2002 Clause 9 & 10.
New Zealand and Australia (C Tick):
IEC 60945:2002 Clause 9.
Environment:
IPx6 and IPx7 - completely waterproof.
Appendix B - Specifications - AP3380 Display