ALL SECURITY FUNCTIONS CAN BE PERFORMED ONLY WITH THE
CONFIRMATION OF THE ADMINISTRATOR’S FINGERPRINT.
SETTINGS
55
EN
The name of the reader
Free entrance mode:
When this mode is switched on, any finger that is placed
on the sensor opens the door. The period during which free entrance mode is
switched on can be adjusted (1 to 600 minutes) and is automatically turned off
after. While the free entrance mode is active, the backlight on the reader is green.
Relay opening time:
The length of time during which the relay is switched on
can be adjusted between 1 and 10 seconds. This setting is useful when using an
electric strike.
Blue backlight:
the blue backlight on the reader can be turned off.
1
2
3
4
Database import/export:
Fingerprint database can be transferred from
one reader to another.
1.
Press the
Export
button on the source reader. This is confirmed by an
administrator.
2.
Make the connection to the new reader and press the
Import
button.
If an administrator has already been enrolled on the new reader, their
fingerprint needs to confirm the import. If the database on the new reader is
empty, this step does not require confirmation.
3.
Activation of the transferred database needs to be confirmed by an
administrator of the source reader.
6
LED settings:
If there is an additional LED lighting in the door, it can be connected
to the system and controlled by the Inokey-manager
(only with door leaf
control unit)
. It is possible to adjust the brightness (1% to 100%) and the
schedule for turning the lighting on/off. If the checkbox next to the 24h is checked,
the LED will be switched on continuously.
5
System:
Software version
7