DIAGNOSTIC MANUAL
REGEN INHIBITORS AND ENTRY CONDITIONS
15.1. REGEN INHIBITORS
Figure 45
Aftertreatment session screen shot
Overview
A Regen may not occur due to any of the following conditions:
•
Inhibitors do not match their expected value
•
Entry conditions have not been met
•
Active fault code(s)
To view the status of Regen inhibitors, use an Electronic Service Tool (EST) with ServiceMaxx™ software, go
to Tests > KOER Aftertreatment Tests > Onboard Filter Cleanliness Test. Select the Inhibitors tab.
152