SETTINGS
1. Hold pressed the F key to enter the setting menu.
2. By up and down keys select the parameter you wish to adjust and press F key to enter into selected parameter. The adjustable
parameter blinks.
3. By up and down key adjust the parameter value. Press F to enter new value and move to next parameter.
4. Exiting setting menu: hold pressed the F key to move back for one level.
Anemometer also returns to normal operation after 2 minutes of inactivity.
PARAMETERS
Parameter:
Description of parameter:
TURN OFF: No/Yes
Powering off the display unit - select Yes and confirm to switch off
Time: 01:58
Time setting - 24 h time format
Date: 01/01/2018
Date setting - day/month/year
Day: Monday
Day setting
Sensor Address: XX
Set the address of receiving sensor
Scan for sensors
Get list of all available nearby sensors
Logging int: 1 min
Logging interval (10 s, 1 min, 10 min or 60 min)
WS unit: m/s
Wind speed unit (m/s, km/h, knots, mph)
Temperature unit:
0
C
Temperature unit (
0
C or
0
F)
WS Cal. Factor: 0.0%
Calibration factor for wind speed (-15,0 ...+15,0 %, in 0,5 % steps)
WD Cal.: 0
0
Calibration of wind direction (-180
0
...+180
0
, in 1
0
steps)
Temp. Cal.: 0
0
Calibration of temperature (-2.0
0
...+2.0
0
, in 0,5
0
steps)
Display Auto Off: No
Automatic display switching off (saving mode/ reducing power consumption)
Yes: display automatically switches off after 2 minutes
No: display is always ON
Reset Data: No
No/Yes
Language: English
English / French
WL12 vXXXXXX
Software version
STORING TO SD CARD
Data in .txt format are stored to SD card every full hour. Each data has date and time stamp.
Logging interval is selectable from 10 sec to 1h. Data are stored in the .txt format and are suitable for processing in programs for
working whit spreadsheet (Excel, Open office, etc...).
Mark “NA” in logged data present missed wind data for marked interval.
Mark “nW” in logged wind direction data present undefined wind direction caused of no wind speed.
There is a rare possibility that individual logged packets could be corrupt due to external causes.
It is recommended to eliminate them during processing logged data.
For each using of new type SD card it is recommended to test writing data to SD card.
STORE DATA FROM SD CARD
It is recommended to store data from SD card every month for preventing data loss because of empty battery in receiver or other
external factors.
DESCRIPTION OF DATA STORED ON SD CARD
[WS]: average wind speed in selected units and logging interval
[WSm]: maximum wind speed in selected units and logging interval
[WSt]: average temperature in selected units and selected logging interval
[WD]: average wind direction in selected logging interval
[RSSI]: average signal strength in selected logging interval
[dd/mm/yyyy]: day/month/year of created logged data
[hh:mm:ss]: hours:minutes:seconds of created logged data
EXAMPLE OF DATA STORED ON SD CARD
Example of logged first 10 wind data from WSD sensor in 10s logging interval. Average [WS] and maximum [WSm] wind speed data
are in units of m/s, temperature in degrees of Celsius [WSt], wind direction [WD] in degrees and signal strength [RSSI] in dB.
<------Navis Elektronika WL12 v270318------->
<------------------------------------------->
<Logging Interval:10s----------------------->
<WS[m/s]-WSm[m/s]-WSt[C]-WD[deg]-RSSI[-dB]-->
<n/a[Data not available] nW[No wind present]>
dd/mm/yyyy,hh:mm:ss, WS, WSm, WSt, WD, RSSI
17/10/2016,00:00:10, 0.9, 0.9, 7,184, 65
17/10/2016,00:00:20, 0.8, 0.9, 7,190, 63
17/10/2016,00:00:30, 0.9, 0.9, 7,187, 65
17/10/2016,00:00:40, 0.8, 0.8, 7,189, 66
17/10/2016,00:00:50, 0.7, 0.8, 7,185, 64
17/10/2016,00:01:00, 0.7, 0.7, 7,190, 64
17/10/2016,00:01:10, 0.6, 0.7, 7,184, 65
17/10/2016,00:01:20, 0.0, 0.0, 7, nW, 63
17/10/2016,00:01:30, 0.6, 0.7, 7,186, 63
17/10/2016,00:01:40, 0.6, 0.7, 7,189, 65