WL12/D DISPLAY UNIT
MANUAL
Model: WL12/D
PREFACE
Thank you for buying Navis anemometer. This manual provides information for the best performance and safe application of the
anemometer display unit. This manual does not cover the anemometer sensors for which the manuals will come separately.
Read this manual carefully before starting the installation. Keep this manual after installation for future reference.
INTRODUCTION
WL12/D is long range receiver/display unit which receive data from NAVIS wind sensor, displays various wind data and store them on
micro SD card. It can be powered by batteries or by micro USB adapter (not enclosed). Built-in battery back-up ensure that the set time
is not reset in case of power interruptions or when unit is switched off.
3.
1.
1. Display
4.
2. SMA antenna connector
2.
3. Signal light
4. Keys
5. SD card insertion
6. USB power supply
6. 5.
Figure 1. (WL12/D
– front panel)
WL12/D is compatible with NAVIS wind sensors: WS 010-1 (wind speed sensor, standard range), WS 011-1 (wind speed sensor,
extended range), WSD 010-1 (wind speed/direction sensor, standard range), WSD 011-1 (wind speed/direction sensor, extended range).
MOUNTING
Select the position where the signal reception is strong enough under all conditions.
There are two holes on back panel of display unit intended for wall mounting (screws are not included).
Display unit can be mounted to the ferrous surface with mounting magnets (optional accessories).
ANTENNA CONNECTION
Connect antenna to SMA connector on display unit only when power supply is switched OFF.
OPERATION
Display unit receives wind and temperature data from sensor, calculates average values and stores them to the memory card. Current
data received from sensor, as well as part of the wind speed history are presented on LCD display. Detailed data in selected interval
are stored on SD card.
All operating parameters can be set using three keys on the receiver unit.
If the display unit is delivered as set, with sensor included, the correct sensor address is already set.
Otherwise please set first the correspondent sensor address. Check the address settings
procedure in chapter “SETTINGS”.
Fresh wind data from active sensor are received every two seconds. If data are not received for more than 20 seconds,
“No data” appears on the display.
SWITCHING ON
Hold pressed the F key for more than 3 seconds for switch ON the unit.
SWITCHING OFF
In the setting menu select “Yes” and confirm to power OFF the unit. Real time clock will continue, graphs will reset and data on SD
card will remain.