WIND LOGGER

 

 

MODELS: WL11/WS, WL11/WDS 

 
 

MANUAL 

 
 
OPERATING 

Sensors continuously measure and transmit data of wind speed, air temperature and wind direction (optionally). 
Display unit receives data, calculates average values and stores them to the memory card. Current data, received 
from sensor, as well as part of the wind speed history are presented on LCD display. All operating parameters can 
be set using three keys on the receiver unit.  
 
DISPLAYING OF DATA:  
Shortly press key F to select between 4 pages  

1.  page - displays current wind speed, temperature, wind direction (optional), date and time 
2.  page - displays 7 days history of average and maximum wind speed 
3.  page - displays 24 h graph of hourly average wind speed   
4.  page - displays 24 h graph of hourly average temperature   

 

SETTING OF PARAMETERS 

Hold the F key pressed to enter the settings menu. Select the parameter you wish to change by using up and down 
keys. Press the F key to enter in the selected parameter and change the value with up and down keys.  
Press the F key to enter a new value into the permanent memory and move to the next parameter. When you have 
set all the parameters, exit the settings menu by holding the F key pressed for 3 seconds.

 

 
DESCRIPTION OF PARAMETERS: 

Time: 12:55     

time setting  - 24 h time format 

Date: 26/12/2015 

date setting  - day/month/year 

Day: Sunday 

day setting 

WS Address: xx 

set the sensor address of your receiving sensor 

WS units: m/s 

wind speed unit (m/s, km/h, knots, mph) 

Temperature unit: 

0

temperature unit (

0

C or 

0

F) 

Logging int: 1min 

logging interval (10 s, 1 min, 10 min or 60 min) 

Display Auto Off: Yes 

automatic display switching off (saving mode/ reducing power consumption) 
Yes: display automatically switches off after 2 minutes 
No: display is always ON 

WS Cal. Factor: 0.0% 

Calibration factor for wind speed (-15,0 ...+15,0%, in 0,5% steps) 

WD Cal. Factor: 0

0

 

Calibration factor for wind direction (-180

0

 ...+180

0

, in 1

0

 steps) 

Te. Cal. Factor: 0

0

 

Calibration factor for temperature (-2.0

0

 ...+2.0

0

, in 0.5

0

 steps) 

Reset Data: No 

No/Yes 

Language: English 

English/French 

 
SENSOR UNIT

 

 

Sensor unit switches ON automatically when the anemometer cups revolve. 

It switches OFF 6 hours after the 

anemometer cups stop revolving.

 In ON state position it sends new wind speed data every two seconds. In 

sleep mode the sensor does not transmits any data. 

 
SENSOR ADDRESS 

Correspondent sensor address has already been preset at the factory. 
Always set the address correspond to the address of the sensor from which the receiver will receive data. Address 
of the sensor is indicated on the label and in the interior of battery compartment.  

 
DISPLAY AUTO OFF  

Activate this mode in the setting menu to prolong battery life. Using this mode, the display switches OFF after  
2 minutes of inactivity. All other functions stay active. Display switches ON with each press of the key. 

 