System Hardware Configuration
Master and Slave stations
When controlling the vessel with the
NAVIS NavDP 4022
, the operator controls with DP-A or DP-B control system
whichever is the Master. The other system is the Slave. All data is duplicated so there is no data loss in case of control
transfer from one OS to another (say, from DP-A to DP-B).
Entire information is available at the every OS in view mode. But only the Master OS allows the operator to input
data, select control mode and control the vessel.
2.3
Main and Portable Control Panels (MCP, PCP)
The MCP is used for:
– Input of control signals from pushbuttons, knob and joystick (if any);
– Setting main DP system operation modes;
– Setting DP system parameters;
– LED Indication;
– Volume control of sound and voice alarms;
– Displaying DP system info on built-in color LCD (for a model with LCD);
– Control transfer between Control Panels.
WARNING!
Control panels and associated Joysticks should be oriented in lon-
gitudinal or transverse direction to vessel’s centerline.
Angular orientation is prohibited as potentially dangerous for ves-
sel control.
WARNING!
Both main and portable control panels should be properly fixed
by using mounting bracket kit.
Unfixed panel using is prohibited as potentially dangerous for ves-
sel control.
The PCP is normally used for vessel movement control from the places differs from DP control center, for example
bridge wings of front console.
Portable control panel general view is shown in Figure 2.6.
Figure 2.6: Portable Control Panel (PCP)
Doc. 000.JDP-10000-OME, rev.3.3.13/“2102.$–17A-Advanced”
24
Содержание NavDP 4000 Series
Страница 88: ...NAVIS NavDP 4000 Operation Manual Figure 5 35 Dark Theme 87 Doc 000 JDP 10000 OME rev 3 3 13 2102 17A Advanced...
Страница 222: ...NAVIS NavDP 4000 Operation Manual Figure 10 74 Drift Plot Window 221 Doc 000 JDP 10000 OME rev 3 3 13 2102 17A Advanced...
Страница 324: ...NAVIS NavDP 4000 Operation Manual Figure H 4 Remote DLS Mode 323 Doc 000 JDP 10000 OME rev 3 3 13 2102 17A Advanced...