background image

8

About the Boiler

2.3.2    Buttons and Command Dial

Using the buttons and the Command dial (

) on 

the front panel, you can turn on or off the boiler, 

monitor the current operation status, and set the 

values required for the boiler’s operation, such as 

space heating and DHW supply temperatures. Refer 

to the following table for detailed information.

a

Back button

Return to the previous menu 

or screen.

b

Mode button

Enter the boiler’s main menu.

c

Power button

Turn on or off the boiler.

d

Command dial

Rotate to switch between 

menu items, or to increase/

decrease values.

Press to make a selection or 

to confirm changes.

c

b

d

a

Содержание NHB-055H

Страница 1: ...tely call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by...

Страница 2: ...9 3 3 Accessing Basic Menu Items 13 3 4 Resetting the Boiler 14 4 Maintaining the Boiler 15 4 1 Cleaning the Boiler 15 4 2 Draining the Boiler 15 4 3 Cleaning the Air Intake Filter 16 4 4 Protecting...

Страница 3: ...uch as property damage DANGER If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance does not have a pi...

Страница 4: ...ler with the front cover opened Doing so may result in fire or carbon monoxide CO poisoning which may result in property damage personal injury or death Do not operate this boiler without proper venti...

Страница 5: ...not use this boiler for anything other than its intended purpose as described in this manual Do not remove the front cover unless the power to the boiler is turned off or disconnected Failure to do so...

Страница 6: ...al glass fuses and automatically cuts off the gas supply Lightning Protection Each boiler is specially grounded both internally and externally to protect against lightning strikes Auto Fan Detection T...

Страница 7: ...is operating in Freeze Protection mode Auto air purge Displayed when an auto air purge is being performed e Cascade Main mode Flashes when configuring a cascade system Turns on solid if the boiler is...

Страница 8: ...for the boiler s operation such as space heating and DHW supply temperatures Refer to the following table for detailed information a Back button Return to the previous menu or screen b Mode button En...

Страница 9: ...llows the boiler to operate at up to 3 different temperatures This built in feature can be accessed from the front panel and eliminates the need for additional accessories that are typically required...

Страница 10: ...n mode rotate the Command dial The space heating temperature is highlighted on the screen 2 Press the Command dial to select the space heating temperature The highlighted section will flash 3 Rotate t...

Страница 11: ...dial to confirm the new temperature 5 Press and hold the Command dial for more than 2 seconds to return to normal operation mode or rotate the Command dial to adjust another zone s temperature Note T...

Страница 12: ...erature range is 104 F 40 C Absolute MIN to 180 F 82 C Absolute MAX You can adjust the temperature ranges in the parameter settings menu The boiler will retain your settings during a power outage 3 2...

Страница 13: ...AD values equal to or lower than 70 Flame Off 8bit AD values equal to or higher than 175 16 Fan Target RPM Set fan speed RPM 17 Fan Current RPM Fan speed RPM 18 Fan Target APS Set APS voltage V 19 Fan...

Страница 14: ...2 Outdoor Reset Curve Outdoor reset curve load type displayed when the outdoor reset option 21 Outdoor Reset is enabled 1 Finned Tube Baseboard 2 FAN Coil 3 Cast Iron Baseboard 4 Low Mass Radiant 5 Hi...

Страница 15: ...ure resistant but it is not waterproof Keep it as dry as possible 4 2 Draining the Boiler You will need to drain the boiler under certain circumstances such as when the boiler is not used for an exten...

Страница 16: ...f the annual maintenance To clean the air intake filter 1 Press the Power button on the front panel to turn off the boiler 2 Disconnect the power supply to the boiler 3 Unfasten the 4 latches 2 at the...

Страница 17: ...ectly The boiler is designed for indoor installation only To ensure that the boiler does not freeze follow these guidelines Do not unplug the power supply cord except for routine maintenance The boile...

Страница 18: ...hat the boiler is frozen contact an authorized technician or licensed professional This boiler requires very little maintenance however a qualified technician should inspect the boiler at the beginnin...

Страница 19: ...injury or death WARNING Follow the service and maintenance procedures given throughout this manual and in component literature shipped with the boiler Failure to perform the service and maintenance co...

Страница 20: ...valve weeping is the valve and not over pressurization of the system due to expansion tank waterlogging or undersizing Checking theWater System 1 Verify all system components are correctly installed a...

Страница 21: ...following items A bucket that is 5 gallons or larger Cleaning solution diluted with water 3 hoses A water circulation pump 2 flush valves if not installed Inspecting the Ignition and Flame Detector E...

Страница 22: ...r s literature for information about the circulation time 10 Rinse the cleaning solution from the boiler a Remove the free end of the drain tube from the bucket and place it in the condensate drain or...

Страница 23: ...is the system in standby Make sure the power is on and plugged into the outlet with the correct voltage Press the Power button and raise the setting temperature Make sure the boiler is turned on Is th...

Страница 24: ...ector E278 Ext Supply Sensor Not Detected Check sensor connections E279 Ext Return Sensor Not Detected Check sensor connections E291 Return Temp Exceeds Supply Check for reversed piping E302 Low Water...

Страница 25: ...y only applies to the replacement of the heat exchanger and does not include labor shipping other parts delivery or installation In order to obtain this warranty the customer must pay the applicable p...

Страница 26: ...e Product at water temperatures outside the factory calibrated temperature limits and or exceeding the maximum setting of the high limit control Subjecting the heat exchanger to pressures or firing ra...

Страница 27: ...Memo...

Страница 28: ......

Страница 29: ...ww navieninc com installers Contact a licensed professional for the affected system for example a plumber gas fitter or electrician When you contactTechnical Support please have the following informat...

Отзывы: