STEP 3    After Installing 

  Opening All the Valves 

 

 

  Operating the Boiler 

 

 

  Measuring the Inlet Gas Pressure 

 

 

 

  Installing the Front Cover 

 

 

  Final Check 

 

A trial run should be performed in accordance with the Installation checklist listed in 
the boiler’s Installation & Operation Manual.

 

Shut off the manual gas 
valve. 

Closed 

Remove the front cover by 
loosening the 4 screws. 

Loosen the screw indicated in the 
figure and connect a manometer 
to the pressure port. Reset the 
manometer to zero before use. 

Open 

Check the inlet gas pressure reading on the manometer. 

Re-open the manual gas valve 
and check for leaks. 

Operate multiple zones that to 
ramp the boiler up to its 

maximum firing rate. 

Adjust the inlet gas pressure 

with gas regulator. 

Gas supply 

If it is out of 

the range, 

  NG:3.5

~10.5

WC 

  L P: 8 . 0

~ 1 3 . 5

W C 

Recommended Gas Pressure Settings: 

1.

 

Turn on the boiler. On the Front 

Panel press the Diagnostics 

button for over 5 seconds until 

1.PAR

  is displayed. 

2.

 

Press the + (Up) button two times 

to change the display to

3.OPR

3.

 

Press the + (Up) button until 

MAX2

  is displayed.   

4.

 

Press the Reset button twice 

to return to normal operation 

mode. 

5.

 

Run space heating. The gas in 

the gas supply line will be 

purged. 

6.

 

Leave the boiler on until the 

boiler shuts down due to a 

lack of gas supply, and then 

turn off the boiler. 

Power ON 

Adjust Temperatures 

 

View Basic Information 

Resetting the Boiler 

When the power is on, the boiler 
supply water temperature will 
appear with the water pressure 
on the front panel display at 

5 second intervals. 

1.

 

Press the Mode button three 

times. “INFO” will appear on 

the display.   

2.

 

Press the + (Up) or – (Down) 

buttons to switch between 

the information types. 

If an error message appears, you 
can try resetting the boiler to 
resolve the problem.   

Note 

Space Heating Temperature   

1.

 

Press the Mode button 

once. The space heating 

icon turns on.   

2.

 

Press the + (Up) or – (Down) 

buttons until the desired 

temperature appears on 

the display. 

If resetting does not solve 
the problem, refer to the 
troubleshooting section of 
the User’s Information 
Manual or contact the 
service center. 
 

DHW Indirect Supply Temperature 

 

 

 

 

 

 

 

 

 

 

3.

 

Press the Mode button 

twice. The DHW heating 

icon turns on.   

4.

 

Press the + (Up) or – (Down) 

buttons until the desired 

temperature appears on the 

display. 

Shut-off Valves 

Navien, Inc. 
20 Goodyear, Irvine, CA 92618 
Tel: (949) 420-0420,    Fax: (949) 420-0430 

www.navien.com 

Gas Valve 

Space Heating System Valves 

Drip rig 

Closed  Open 