Navien NFC-250/175H Скачать руководство пользователя страница 1

28884 049

1

  Unpacking

 

>

 

Navien 
Condensing 
Boiler

User’s Information 
Manual, 
Installation & 
Operation Manual

Quick 
Installation 
Manual

Air Vent

High Altitude 
Conversion Kit 
(Natural Gas Only)*

Propane 
Conversion 
Kit*

Tapping Screws 
and Anchors

Pressure Relief 
Valve, Heating

2 in Vent 
Termination 
Caps

Air Vent 
Bushing  
(

3

/

in to 

1

/

in)

Outdoor 
Temperature 
Sensor and Cable

Condensate 
Trap

Wall Flanges

Wall Mounting 
Bracket

Universal 
Temperature 
Sensor

 

Spare Parts

* High Altitude Conversion kit and Propane Conversion kit are attached 

to the inside of Product’s cover.

Model

NFC-250/175H

NFC-250/200H

Quick Installation Guide

STEP 1  Before Installing

Read the Installation & Operation Manual before installing. 

This product must be installed and serviced by a licensed plumber, 
a licensed gas fitter, or a professional service technician. Navien is 
not liable for any damages or defects resulting from improper 
installation.

 

WARNING

Follow all local codes and/or the most recent edition of the National Fuel Gas Code (ANSI 
Z223.1/NFPA 54) in the USA, or the Natural Gas and Propane Installation Code in Canada 
(CAN/CGA B149.1).

Safety

DO NOT install the boiler in areas with excessively high humidity.

Location Requirements

Select the best location on “Choosing an Installation Location” in the Installation & 
Operation Manual.

Allowable minimum clearances

Top

Back

Side

Side

Front

Bottom

Clearance

Indoor Installation

Top

9 in (229 mm) minimum

Back

0.5 in (13 mm) minimum

Front

4 in (100 mm) minimum

Sides

3 in (76 mm) minimum

Bottom

12 in (300 mm) minimum

STEP 2  Installing

  Checking the Rating Plate

 

>

 

This boiler is configured 
for Natural Gas from the 
factory. If conversion to 
Propane Gas is required, 
the Propane Conversion 
Kit supplied with the boiler 
must be used.

 

WARNING

 

e

Before connecting the gas supply, determine the gas type and pressure for the boiler by 
referring to the rating plate. Use only the same gas type indicated on the rating plate. Using a 
different gas type will result in abnormal combustion and malfunction of the boiler. Gas 
supplies should be connected by a licensed professional only.

 

e

The appliance and its gas connection must be leak tested before placing the appliance in 
operation.

 

e

This boiler cannot be converted from natural gas to propane or vice versa without a Navien gas 
conversion kit. Do not attempt a field conversion of this boiler without a Navien gas conversion 
kit. Doing so will result in dangerous operating conditions and will void the warranty.

Navien Inc. is not liable for any property damage and/or personal injury resulting from 
improper conversions.

  Mounting on the Wall

 

>

 

 

CAUTION

Do not install the boiler on dry walls without proper reinforcement.

Drill in the supplied anchor bolts 
after considering where the vent 
termination will be located.

1

Lift up the boiler, rest the unit on the hooks 
provided on the wall bracket on the wall.

Secure the mounting bracket to the wall 
with the tapping screws and anchors.

2

  Removing the Front Cover

 

>

 

Unclasp the 4 buckles that fix 

the cover to the boiler, and then

remove the cover by lifting it 

and pulling it outward.