Operating the Boiler 11
3.3 Viewing Basic Information
To view information about the boiler, press the Menu button
(
), and then select “2. Status Information”.
Press the Up button ( ) or the Down button ( ) to switch
between the information items. Press the OK button ( ) to
select an item and view the information.
Press the Back button (
) to exit information view mode.
Item
Description
1. Operation State
Current Operation State
2. Heat Capacity
Heat capacity (%)
3. CH Set Temp
Central heating set temperature
(°C)
4. DHW Set Temp
DHW set temperature (°C)
5. Supply Temp
Heating supply temperature
(°C)
6. Return Temp
Boiler return temperature (°C)
7. Outdoor Temp
Outdoor temperature (°C)
8. Inlet Temp
Inlet temperature (°C)
9. DHW Temp
DHW temperature (°C)
10. Water Flow
Water flow rate (LPM)
If the rate is 0, “Calculation” will
be displayed.
11. Water Press
Water pressure (bar)
12. Flame Value
Flame detector AD value
●
Flame On: 8bit AD values
equal to or lower than 70
●
Flame Off: 8bit AD values
equal to or higher than 175
13. Fan Target RPM
Fan target speed (RPM)
2. In normal operation mode, press the Up button ( ) The
DHW temperature ( ) is highlighted on the screen.
3. Press the OK button ( ) to select the DHW temperature
temperature ( ). The highlighted section will flash.
4. Press the Up button ( ) or the Down button ( ) until the
desired temperature appears on the display. You can adjust
the temperature while the display is flashing. Once the
display stops flashing, the temperature setting is stored.
Note
●
Take note of the original water temperature in case
you want to restore it to the default.
●
The default DHW temperature range is 30°C to
65°C.
●
The boiler will retain your settings during a power
outage.
●
The DHW temperature cannot be adjusted, when
the Heat Demand function is set to OpenTherm.