8. Replace the PCB tray back into the water heater and secure it with the two

 

screws.

 

9. Close the front cover and secure it with the 4 screws.

 

 

 CAUTION 

Before disconnecting cables inside the unit, label all cables. Wiring errors can 
cause improper operation and dangerous situations. Verify wiring connections 
and unit operation after servicing. 

3. Wiring the Device 

This section provides information required to plan and install the system wiring. 

 

3.1 Connecting Wired Switches 

Navien HotButton Kit

 

provides terminal contacts for wired switch applications. 

Refer to the following diagrams to connect a wired switch, or  multiple wired 
switches to the HotButton controller. 

Use UTP cables or cables with a diameter greater than AWG 24. 

 

y

Make sure that the total cable length does not exceed 328 feet (100 meters). 

y

Additional push button switches (#GXXX001426) and wall plates (#GXXX001427) can be 
purchased through Navien.

y

You can connect up to 10 push button switches to one HotButton controller. 

y

Use spade connectors at the end of the cables to securely install the cables to 

 

y

Multiple wired switches may be connected to the same terminal contacts. 

y

the terminal contacts. 

 

Note 

 

Note 

3.2 Connecting the Main Control Connector 

To connect the  HotButton

 Kit to 

the 

Navien 

NPE -180A/210A/240A

 

water heaters, use 

the 13-pin main control connector supplied with the HotButton Kit.

Connect one end of the cable to the connector socket on the 

HotButton

HotButton Kit PCB.

 

Then, connect the other end to the  connector socket on the  NPE-180A/210A/240A

 water heater PCB. 

 

 

 

 

4. Configuring the HotButton  Operation  

This section provides the information required to set the desired options for the NPE-
180A/210A/240A water heater system with the HotButton Kit.

4.1 Entering the R&D Information Menu 

This section describes how to enter the R&D information mode to configure various 
parameters and control system functions. 

4.1.1 Entering the R&D Information Menu 

Follow the instructions below to enter the R&D information menu. 

1. On the Front panel, press the Power button to turn off the water heater.

 

2. Enter the R&D information menu by pressing the Up (+) button three times, the 

Down (-) button three times, and then the Up (+) button four more times.

 

 

 

No. 

Mode 

Display 

1 Technical 

Information 

 

2 Parameter 

Information 

 

4. To return to the previous menu (R&D information menu), press the [Reset] 

button once.  

 

4.2 Parameter Setting for the  Recirculation Pump Operation

* The default setting (5 minutes)  is recommended for most applications. Set the 
   duration  to 5 minutes or less to conform to the energy saving requirements in
   California.

 

Item 

Description 

Display 

(P.12) HotButton

 

pump cycle 

time

 

Pump duration for the recirculation 
operation by HotButton  

signal    

 

Range 

Description 

Display 

1–5(min)

Sets the pump duration for the 
recirculation operation by 
HotButton

 

signal (default: 5 min*).

 

 

5. HotButton  Kit Operation Details

 

This section provides technical information required to properly operate the 
HotButton recirculation functions  with the HotButton Kit.

%QORCVKDNG9CVGT*GCVGT6[RGU

HotButton Kit  

is compatible with “A”   

type NPE water heaters only. 

This device is NOT compatible with "S" type NPE water heaters. 

Set Parameter #12 (P. 12) to configure the internal circulation pump cycle time when 
a HotButton signal is detected. Refer to 

*QV$WVVQP1RGTCVKQP%QPFKVKQP6CDNG

for different operating conditions. 

4GEKTEWNCVKQP1RGTCVKQP

 D[VJG*QV$WVVQP-KV

With the  HotButton Kit

 

installed, the water heater’s built- in  intelligent  preheating 

 feature is disabled

 

(recirculation operation does not run unless a HotButton signal is

received). Refer to 

*QV$WVVQP1RGTCVKQP%QPFKVKQP6CDNG

for different operating 

conditions.

The HotButton recirculation cycle must be fully completed before a new input signal can 
be received.  Any new input signals will be ignored during operation. The cycle cannot be 
extended during operation.

2TKQTKV[KP1RGTCVKQP

When the HotButton Kit

 

is installed,

- Timer settings with the remote controllers are disabled.

 

- Recirculation settings available at the water heater’s   Front  panel are disabled.   

   

 

6. Maintenance 

Please refer to the NPE Installation Manuals for more information on maintenance 
and service.

 

LIMITED WARRANTY NAVIEN, INC. 

 

Warranty Period 

Navien products come with a limited warranty covering parts. The following 
warranty periods begin to run from the date of original installation. The date of 
original installation must be provided to Navien, and upon request, proof of the 
original installation date must also be provided to Navien. When the product is 
installed in a new construction, the commencement date shall be dated upon which 
the end-user takes title to the property. 

APPLICABLE WARRANTY PERIOD 

Period of Coverage 

All other parts and components 

3 years 

Warranty Claim Procedures 

To obtain warranty repair service, the end user or homeowner must contact the 
original installer of your Navien product. If the original installer cannot be identified, 
the end user or home owner may contact Navien’s Technical Administration 
Department at (800) 519-8794. Proof of purchase is required to obtain warranty 
service. 

Warranty Service 

At its option, Navien will replace the defective component (part), in accordance with 
the terms of this Limited Warranty, if it fails in normal use and service during the 
applicable warranty period identified above. The replacement component must be 
Navien original factory component. Navien, at its sole discretion, may replace the 
product with a new or refurbished product of comparable quality and design. The 
replacement component or product will be warranted only for the unexpired 
portion of the original component’s applicable warranty period. Payment for labor in 
completing the warranty service is subject to Navien’s prior written approval and 
shall be subject to Navien’s schedule of approved labor allowances. 

 

 

Service

 

If your HotButton  

Kit requires service, you have several options for getting 

service:

 

y

Contact  Navien Technical Support at 1-800-519-8794 or on the website:
www.navien.com. For warranty service, always contact Technical 
Support first. 

y

Contact the technician or professional who installed your  HotButton 
Kit.

 

y

Contact a licensed professional for the affected system (for example, a 
plumber or electrician). 

 

Version: 1.5 (Jan.  04. 2016)

 

 

 

3. In the R&D information menu, use the Up (+) or Down (-) buttons to move to 

2.PAR (Parameter information mode), and then press the Info button. 

 

When you connect the push button switches to the controller, you can run cables from each 
switch directly to the controller and connect them to the same terminal. Or, you can run a 
common branch circuit that runs from the controller and connect each switch to the branch.

[Multiple switches connected directly to the same terminals at the controller]

[Multiple switches connected to a common branch circuit]

CE1

CE2

U1

C1 C2

C7

R6

PC1

12 V 

5 V 

 SIGNAL
 

SIGNAL 1

GND

R5

R9

R8

C3
R1

R2

R7 

D1 

CON3

CON5

CON2

CON1

 

SIGNAL 2

 

SENSOR I

RA1

 

 

CE1

CE2

U1

C1

C2

C7

R6

PC1

12 V 

5 V 

 SIGNAL

 

SIGNAL

 1 GND

R5

R9

R8

C3

R1

R2

R7 

D1 

CON3

CON5

CON2

CON1

 

SIGNAL

 2

 

SENSOR I

RA1

7

R5

C3

C

*QV$WVVQPRWORE[ENGKPVGTXCNVKOG2

Refer to the tables

Follow the instructions in 

4.1.1 Entering the R&D Information Menu

 to enter the 

parameter setting mode . Press the up (+) button until you reach the items to verify or 
configure.

 on page 7 to set the

 

pump duration for the recirculation operation by 

HotButton  

signal. 

%QPHKIWTKPIVJG4GEKTEWNCVKQP1RGTCVKQPD[VJG*QV$WVVQP-KV

The following table lists HotButton operation conditions based on different applications.

*QV$WVVQP1RGTCVKQP%QPFKVKQP6CDNG

 

100 °F (38 °C)

1-5 min (default: 5 min). When the interval is set to 5 min, the pump 
operates in 4 min 50 sec intervals.

HotButton 
pump cycle 
time (P.12)

HotButton OFF
temperature

When the HotButton pump cycle interval time set at P.12 has elapsed

Operation

 

Operation

 

 

 

HotButton OFF
condition #1

Conditions

Отзывы: