Navien HotButton NPE-ODC Скачать руководство пользователя страница 1

 

 

 

 

Installation Manual 

 

Add-on Board Installation Kit 

For NPE-180A/210A/240A 

This device is designed to work with 
NPE-180A/210A/240A models ONLY.

 

 
 

 

 

 

 WARNING 

All Installations should be done only by a qualified expert and in accordance 
with the appropriate Navien manual. Installing an electric appliance with 
improper methods or materials may result in serious injury or death due to fire. 
 

ELECTRICAL SHOCK HAZARD. Disconnect power before installing or servicing. 
Otherwise, electrical shock may result causing severe personal injury, death, or 
substantial property damage. 

 

All wiring must be installed in accordance with local regulations of the 
installation site. 

NPE-ODC

1.2 Specifications 

Refer to the following table for product specifications. 

Items 

Specifications 

Model name 

 

Device type 

Add-on input board for Navien NPE-180A/210A/240A 
water heaters for HotButton Recirculation

Installation type 

Snap-on  
(onto the NPE-180A/210A/240A water heater PCB tray) 

Connections

 

Main connector socket to water heater

 

Main control connector (13-pin cable) 

 

Switch terminal*

 

Contacts for  multiple push button switches

 

* Push button switches do not require a power source. Multiple switches may be 

*  SIGNAL1 contacts are for optional wireless push buttons or motion sensor accessories.

** SENSOR I contacts are connected with a piece of metal plate by default. Remove
     the metal plate before connecting a temperature sensor to the circuit board. 

installed in parallel to activate DHW recirculation from various locations. 

 

 

1.3 Device Layout 

Refer to the following diagram for the product layout.

 

1.3.1 Wiring Connection Table 

Terminal Wiring 

Connection 

Signal1

 

12 V 

 

 

Signal 

 

 

GND 

 

Signal2  
(Not polarity sensitive) 

Push Button Switch Contact #1

 

Push Button Switch Contact #2

 

Sensor I

 

 

 

 

2. Installing the Device 

This section provides information required to install the HotButton Kit  

in an NPE-180A/210A/240A water heater. 

 WARNING 

Ensure that you have turned off the power to the water heater before installing the device.

2.1 Basic Principles 

The following diagram shows the basic operation of an NPE-180A/210A/240A water heater recirculation system with the HotButton Kit.

2.2 Installing the Device in an NPE-180A/210A/240A 
Water Heater 

Follow the instructions to install the HotButton  

Kit in an NPE-180A/210A/240A

 

water heater.

 

1. Turn off the power supply to the water heater. 

2. Remove the water heater’s front cover by loosening the four screws securing it 

to the case. 

4. Remove the two screws holding the PCB tray in place and pull out the PCB tray 

from the unit. 

3. Make sure that the 2-way valve is turned to the EXTERNAL setting, once the  

 

 

plumbing system is completely installed. 

 

4. Verify the current PCB version of the NPE water heater. 

y

For OLD PCB Version KDC-330-5M P12

: The PCB must be replaced with an 

updated version. Remove all the cables and connectors from the PCB and 
replace with the latest PCB version that is compatible with the HotButton  
Kit. Reconnect all the cables and connectors to the PCB. Proceed to the next 
step.

 

y

For NEW PCB Version KDC-330-5M P20

: The existing PCB can be used. Pull 

out the PCB from the tray, but do NOT disconnect any cables or wires. 
Proceed directly to the next step. 

5. Install the  HotButton  Kit onto the NPE-180A/210A/240A water heater’s PCB 

tray. Align the latch  at the back of the case with the front lip of the PCB tray. 

 

 

6. Align the two latches at the back of the HotButton  

Kit

 

with  

the  two catch

 

bars at

 

the back of the water heater’s PCB tray. Then pivot the HotButton Kit

onto the PCB tray until the latches snap -on to the catch bars. 

 

 

7. Connect cables to the HotButton  

Kit.

For more details, refer to  “

3. Wiring The Device.

 

When Installing this Product: 

1. Read these instructions carefully. Failure to comply could damage the 

product or cause a hazardous condition. 

2. Check the ratings provided in the instructions and on the product to make sure the 

product is suitable for the application. 

3. Installers must be trained, experienced, and licensed service technicians.

 

4. Follow local codes for installation and application requirements.

 

After the installation is complete, verify proper operation of this product by following the 
instructions provided in this manual. 

 

 

All wiring must be installed in accordance with local codes and regulations. 
This accessory will not operate in conjunction with the Navien H2Air system.

 

 

Note 

1. About the HotButton Kit

 

The Navien HotButton

 Kit 

is 

an 

add- on 

input 

board

 

for the Navien NPE -180A/210A/240A

 

water heaters. It adds signal input functions to the NPE-180A/210A/240A water heaters

 

for 

more efficient DHW hot water recirculation

 

functionality.

 

With  the  HotButton  Kit,  DHW  recirculation  is  carried out  exactly when  the  actual 
demands arise.

 

This prevents energy loss caused by unnecessary operation of the burner

and pump throughout the day.   

   

 
The  

HotButton Kit

 

receives  signals  from multiple  push  buttons  installed in various

 areas  and performs optimal DHW recirculation only when there is a demand for 

 

1.1 Included Items 

 

The product is supplied with the   following items.

. Make 

sure 

that

 the 

installation 

kit 

contains all the items before installing the product.

 

Main Connector - 13-pin to 

Navien NPE 180A/210A/240A

Water Heaters

Installation Manual

Navien HotButton Kit

Wall Plate 

(#GXXX001427)

Temperature Sensor

(#GXXX001640)

Push Button Switch

 (#GXXX001426) 

hot water.    

Contacts for wireless push button or motion sensor 
connection

Contacts for temperature sensor connection

5 V

Note

This device is not compatible with
cascade (multi-unit) installations. 

Note

* When the optional temperature sensor is installed, it must be insulated.  
   The sensor wire may be extended by up to 100 ft (30m) using 22AWG wire.

Add-On Controller