PARTS DIAGRAM

No.

1

2

3

4

5

6

7

8

No.

9

10

11

12

13

14

15

O.F.P.Cable

Front Panel

Control Valve

Copper Pipes

Junction Box Cover

Compressor

Running Capacitor

Circuit Board

Electronic Starter

Starting Capacitor

Fan

Fan Cover

Power Supply Cord

Base

Cover

WIRING DIAGRAM

No.

1

2

3

4

5

6

7

8

9

Graphics Code

XS

FR

ES

M1

C1

C2

ST

TC

HP

Power

 

Outlet

Overload Protection Device

Electronic Starter

Compressor Motor

Start Capacitor

Running Capacitor

Motor Thermal Potectors

Electronic Transformer

High Pressure Switch

No.

10

11

12

13

14

15

16

17

18

Graphics Code

LP

OFP

d1

d2

d3

SW

HL

CTR

K1

Low Pressure Switch

80% O.F.P. Swiich

Green Indicator

Red Indicator

Power Button

Indicating Lamp

Control Moduel

Relay

Component

Component

Component

Component

Empowering you to work smarter

Empowering you to work smarter

Содержание NRRD

Страница 1: ...User Manual NRRD SAVE THIS MANUAL FOR FUTURE REFERENCE Recovery Unit NAVAC Inc www NavacGlobal com MADE IN CHINA Tel Fax 1 877 MY NAVAC 877 696 2822...

Страница 2: ...s properly connected and grounded If the original power supply cord is damaged choose the properly rated replacement or you may buy the replacement directly from your authorized wholesaler If the unit...

Страница 3: ...ess than 30 bar 435 1 PSI After the high pressure alarm light turns off press the reset button and turn on power to restart the compressor If the high pressure protection trips please find out the cau...

Страница 4: ...02A R 404A R 407A R 407B R 410A R 507 R 22 R 401A R 401B R 402B R 407C R 407D R 408A R 409A R 411A R 411B R 412A R 502 R 509 Oil less Air cooled Piston style 558 psi 38 5 bar Max Current Draw Compress...

Страница 5: ...Code XS FR ES M1 C1 C2 ST TC HP Power Outlet Overload Protection Device Electronic Starter Compressor Motor Start Capacitor Running Capacitor Motor Thermal Potectors Electronic Transformer High Pressu...

Страница 6: ...er switch press START button for liquid recovery 2 2Turn the switch to position 3 turn on the power switch press START button for vapor recovery Note Turning the switch to position 1 gets a stable rec...

Страница 7: ...ed Start operation Warning When the electric scale shows that the refrigerant in the tank has reached 80 capacity turn the power off and close the tank valves Open the vapor and liquid valves of the s...

Страница 8: ...13 12 TROUBLESHOOTING Empowering you to work smarter Empowering you to work smarter...

Отзывы: