Operation Instruction
03
02
2. Get the clamp placed.
Ÿ
Keep the lever open and put in the clamp. A locked lever resists the clamp being placed.
Ÿ
Push the lever inward to lock the clamp.
3. Press the START button to flare.
Copper
Limit baffle
Clamplegs
Figure 1
Figure 2
Clamp
Lever
Locking the clamp
Figure 3
Caution:
Make sure hash marks lineup. Otherwise
it may cause a defective flare and
damage the clamp.
Caution:
Ÿ
Don’t open the lever during flaring, otherwise the automatic flaring stops.
Ÿ
If it happens, press the reset button 2 seconds to draw back the cone.
Ÿ
Make sure the clamp is still horizontally placed.
Ÿ
Press inward the lever to lock the clamp again.
Ÿ
Press the start button to reflare.
Light
Flaring
Hold 2s to Reset