OPERATING INSTRUCTION 

4). Liquid push/pull mode 

A Notice 

A digital scale is needed to monitor the 
recover process to prevent overfilling. 

Vapor valve 

r-:::;:====:::::,,.,� 

QDII 

liquid valve 

____,_ ___ am 

Liquid valve 

lopen(2) 

Refrigerant 

equipment 

(  NRDC4M  ) 

Refrigerant tank 

Use NVR1 valve core removal for faster recovery speed.

Ready for operation 

Connect the hoses correctly and firmly. 

( Please refer to the connection diagram) 

Make sure all valves are closed. 

Start operation 

1.Open the vapor valve, liquid valve of the HVAC system. 

2.0pen the vapor valve, liquid valve of the tank. 

3.Press "START" button to start machine, then ii starts liquid 

push/pull mode. 

4.Tum the knob to "Recover". 
If the reading on the scale keeps the same or changes 

slowly, it means liquid in HVAC system has been 

recovered and vapor recovery mode can be underway. 

12 

5.Turn the knob slowly to "Purge" and start self purging 

mode for the liquid. 

6.Turn the knob to "Close". 

7 .Close the vapor valve, liquid valve of the HVAC system. 
8. Close the vapor valve, liquid valve of the tank. 

9.Reconnect the hoses and start recovery mode for the 

vapor. 

Finish operation

Empowering you to work smarter 

NA

Yf

AC 

TROUBLE SHOOTING 

PROBLEM 

LCD does not 

work after 

power is on 

Machine does 

not run after 

pressing START 

Machine stops 

after running a 

period of time 

CAUSE 

1.  Power cord is damaged. 

2.  Inner connection is loose. 

3.  Connect to J6 is damaged. 

4.  Malfunction of circuit board. 

1. HP Cutoff, or OFP Cutoff works 

(screen shows) 

2. Fault 2 or Fault 3 

3. Fault 4 or Fault 8, over load 

4. Fault 5 

5. Fault6 

6. Fault 7 or Fault 12 

7. Fault g or Fault 10 

8. Fault 11 

9. Button is damaged 

10. Circuit board is damaged 

1.  Misoperation causes HP Cutoff. 

2. 

Thermal protector is on and shows 

Fault 7. 

3.  Refrigerant is 80% in the tank, and 

O.F.P Cutoff shows. 

4.  Recovery work is finished. LP 

Cutoff shows. 

E1 shows at LP  Pressure sensor is not connected well 

or HP 

or is short circuit. 

SOLUTION 

1.  Replace cord. 

2.  Check the connection. 

3.  Replace the connect. 

4.  Replace MCB or DCN circuit board. 

Contact NAVAC techsupport. 

1. Check if the connection between 

HP or OFP to DCB is good. 

2. Adjust to correct voltage. 

3. Turn knob to close. Press START. 

4. Check if the connection between TS 

and MCB is good. If good, contact 

NAVAC techsupport. 

5. Check if TS connection is damaged. 

If not, contact NAVAC techsupport. 

6. Check if the connection between TP 

and MCB is good. If good. 

7. Replace digital control board. 

8. Replace circuit board. 

9. Cool down the machine. 

10. Check if connection wire between 

motor and MCB is good.If good, 

contact NAVAC techsupport. 

1.  Refer to section 6 of OPERATION 

on page 3. 

2. 

When Fault 7 and Restart flash, 

press START. 

3.  Replace the tank. When O.F.P 

Cutoff and Restart flash, press 

START. 

4.  Could restart with pressure rise.

Check if the connection between LS or

HS to DCB is good. If good, replace 

pressure sensor. 

1.  The pressure of the refrigerant tank  1 .  Cooling the tank help decrease the 

Slow recovery 

is too high. 

pressure. 

rate 

2.  Piston ring of compressor is 

2.  Contact NAVAC techsupport. 

damaged. 

Not evacuate 

1.  Connection hose is loose. 

2.  Machine leaks. 

1. Tighten the connection hoses. 

2.  Contact NAVAC techsupport. 

13 

Содержание MASTER Series

Страница 1: ...5 Commonwealth Ave Woburn MA 01801 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Страница 2: ...tor if the above problem is found Please read the manual carefully and use the unit according to the product operating procedures Safety indication Awarning This mark indicates procedures that must be...

Страница 3: ...itionting and refrigerationsystems containningmorethan 200 lbs of high pressure refrigerant The tank and hose used must comply with the local regulations 02 Empowering you to work smarter N AYf AC OPE...

Страница 4: ...ERATION PANEL Start Stop LP Switch Units Zero IN COMPLETE OUT 1111 1111 lnHgKpaPslKgfbarMPa lnHgKpaPslKgfbarMPa LP Cutoff HP Cutoff LP 123 Restart 4 Fault lJlJ Q 7 O F P Cutoff p jfl Starts and Stops...

Страница 5: ...short circuit Fault 7 Temperature protector open Fault 8 Motor stalling Fault 9 Motor wire short circuit Fault 1O Motor wire short circuit Fault 11 PFC over electric current Fault 12 Motor temperatur...

Страница 6: ...valve and liquid valve ofAC system are in close position 2 Confirm the vapor valve and liquid valve of recovery tank are in close position 3 Open the vapor and liquid valves of manifold gauge 4 Loose...

Страница 7: ...ration Knob to A and adjust mainknob From 1 to 0 If it is difficult to start turn to CLOSE when liquid turn to PURGE when vapor then press START to restart the machine and turn to the required positio...

Страница 8: ...creen shows 2 Fault 2 or Fault 3 3 Fault 4 or Fault 8 over load 4 Fault 5 5 Fault6 6 Fault 7 or Fault 12 7 Fault g or Fault 10 8 Fault 11 9 Button is damaged 10 Circuit board is damaged 1 Misoperation...

Отзывы: