NAUTILUS MX3-500 SWITCH PANEL:
(Shown with optional Heater & Pump-Out)
Vacuum #2 – Power from Cord #1.
When the switch is turned to the ON position
power is supplied to the vacuum motor.
(2-Stage Vacuum)
Solution Pump Switch – Power from Cord #2
.
When the switch is turned to the ON position
power is supplied to the solution pump motor.
When not using solution (Extracting only) do not
turn this switch ON.
Vacuum #1 – Power from Cord #1.
When the switch is turned to the ON
position power is supplied to the vacuum
motor. (2-Stage Vacuum)
Cooling Fan – Power from Cord #1.
The cooling fan is not controlled by any switch.
As soon as Cord #1 is plugged in the cooling fan will turn on to exhaust air from the base.
Optional Heater – Power from Cord #2.
When the switch is turned to the ON
position power is supplied to the 1750W
heating element.
OPTIONAL - Waste Pump Switch
Power from Cord #2.
Do not turn Waste Pump
Switch ON unless a hose is connected to the
Pump-out Outlet port.
For pump protection there is a pressure switch
which will turn the waste pump off if the
pressure in the discharge line gets too high, as it
would if the pump was turned on while the
outlet cap was still in place.
Содержание MX3-500
Страница 1: ...1 REVISED 01 29 2015 LMANN05 MX3 500 Nautilus Operating Manual...
Страница 39: ...39 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740...
Страница 40: ...40 Optional Pump Out Pump AP37 PARTS ASSEMBLY...
Страница 41: ...41 1 2 4 4 6 7 10 2 3 39 8 11 3 5 8 9 8 9 12 9 8 9...
Страница 45: ...45 48 49 49 47 47 47A 47 47A 47 47A 51 51 37 9 54 64 9 54 64 9 54 64 52 VACUUM MOUNTS CONNECTIONS 47A...
Страница 48: ...48 2 39 1 72 73 73 67 9 30 31 82 83 2 83 82 84 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK...
Страница 50: ...50 96 91 97 9 88 111 94 105 93 OPTIONAL PUMP OUT CONNECTIONS 99 95 110...
Страница 51: ...51 FLOW 81 92 91 99 96 9 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 39 9 110 97...