20
8. Connection of Optional Pump-Out Hose:
If your machine has the Optional Auto Pump-Out System you may want to connect the Pump-Out Hose.
The pump-out hose is a 50’ section of 3/4” garden hose. (Use of smaller diameter hose may reduce flow.)
•
Remove the cap from the pump-out outlet fitting on the back of the machine.
•
Connect the pump-out hose to the outlet fitting.
•
Place the other end of the hose in a commode or drain connected to the sanitary sewer system.
•
Secure hose end to prevent movement during pumping.
Use defoamer to prevent foam build-up in recovery tank during cleaning and to keep
foam/moisture from entering vacuums.
Use Hydro Filter II inline filter to trap and remove debris from the waste water before it enters
the recovery tank. Excess debris in recovery tank may clog Pump-Out filter. Clean Filter as
needed during use.
Do not turn the Waste Pump switch ON unless pump-out hose is connected and has been
routed to a proper drain.
The Waste Pump does not use a float switch and will run as soon as the Waste Pump switch is
turned ON. It is made to run continuously while cleaning, as this type diaphragm pump can
run dry without damage.
When ready to begin cleaning, turn the Waste Pump switch to the ON position.
If not using the waste pump-out, the pump-out hose does not need to be connected. When the recovery tank
fills during cleaning, the float assembly in the vacuum inlet filter will rise and will automatically shut off the
vacuum air flow to prevent the recovery tank from overfilling and waste water from getting into the vacuums.
When this occurs:
•
Immediately shut off the vacuum switches.
•
Drain the recovery tank.
o
Turn off the pump switch while draining the tank.
o
Turn pump switch back upon resumption of cleaning.
•
Close the drain valve and turn the vacuum switches back on when
ready to resume cleaning.
If the pump-out or vacuum shutoff is not working properly, refer to the
trouble shooting guide or contact your distributor for advice or assistance.
Connect the Female
Garden Hose Fitting
end of the Pump-out
Hose to the outlet fitting
on the back of the
recovery tank. Place the
other end of the pump-
out hose in a sanitary
drain.
Float Shutoff Assembly
Draining the Recovery Tank
Pump-out Filter
Содержание HYDRO-FORCE MX200M
Страница 1: ...1 Revised 04 26 22 Nautilus Operating Manual...
Страница 9: ...9...
Страница 28: ...28...
Страница 29: ...29...
Страница 30: ...30...
Страница 31: ...31...
Страница 32: ...32...
Страница 33: ...33...
Страница 34: ...34...
Страница 35: ...35...
Страница 36: ...36...
Страница 37: ...37...
Страница 38: ...38...
Страница 39: ...39...
Страница 40: ...40...
Страница 41: ...41...
Страница 42: ...42...
Страница 43: ...43...
Страница 44: ...44...
Страница 45: ...45...
Страница 46: ...46...
Страница 47: ...47...
Страница 48: ...48...
Страница 49: ...49...
Страница 50: ...50...
Страница 51: ...51...
Страница 52: ...52...
Страница 53: ...53...
Страница 54: ...54...
Страница 55: ...55...
Страница 56: ...56...
Страница 57: ...57...
Страница 58: ...58...
Страница 59: ...59...
Страница 70: ...70...
Страница 72: ...72 Parts 4 6 7 7A 3 5 1 Section 3 8 9 12 39 2 10 11...
Страница 76: ...76 47 47 47 47A 51 51 37 9 54 64 VACUUM MOUNTS CONNECTIONS 52 47A 49 49 48...
Страница 77: ...77 117 PUMP BOTTOM VIEW OF BASE 68 112 57 56 61 62 9 54 63 55 60 3 59 39 37 121 44 67...
Страница 78: ...78 BOTTOM VIEW SOLUTION TANK BASE SKIRT 80 55 36 36A 78 34 39 9 41...
Страница 79: ...79 2 73 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK 1 72 9 30 31 82 67 39 83 82 2 84 83...
Страница 81: ...81 OPTIONAL PUMP OUT CONNECTIONS 95 105 93 96 94 97 9 89 91 99...
Страница 82: ...82 FLOW 81 92 91 99 96 9 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 39 9 97 89...
Страница 83: ...83 HEATER PARTS 42 42A 98 114 71...
Страница 84: ...84 Pump Out Pump PARTS ASSEMBLY...
Страница 85: ...85 Internal Pump Out...
Страница 86: ...86 Extreme Vacuum Base Fans...
Страница 87: ...87 Extreme Vacuum Motors and 500 PSI Pump...