![Nautilus Be Strong Commercial R916 Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/nautilus/be-strong-commercial-r916/be-strong-commercial-r916_service-manual_711571048.webp)
48
Mechanical Procedures
figure 34 -
figure 35 -
figure 36 -
figure 37 -
U916 Procedures
REMOVING THE UPPER HANDLEBAR:
Tools needed:
Phillips screwdriver or Cordless drill with Phillips tip
6 mm Allen wrench
Step 1:
Remove the console according to REMOVING THE
CONSOLE procedure.
Step 2:
Remove the four Allen screws attaching the Handlebar
to the frame with a 6mm Allen wrench. See
Figure 34
.
Step 3:
Carefully pull the cables out from the Mast (
Figure 35
).
Step 4:
Reverse the steps to install a new Handlebar assembly
on the machine.
REPLACING THE UPPER RIGHT OR LEFT CHR PLATES:
Tools needed:
#0 Phillips screwdriver
Step 1:
Carefully remove the two screws from the rear CHR
plate and separate the plates. See
Figure 36
.
Step 2:
Disconnect the black CHR wire from the rear plate and
place to the side. See
Figure 37
.
Содержание Be Strong Commercial R916
Страница 4: ... Contents ...
Страница 10: ...10 ...
Страница 14: ...14 ...
Страница 22: ...22 ElectricalTroubleshooting ...
Страница 34: ...34 ElectricalTroubleshooting ...
Страница 66: ...66 ...