Service Manual Chapter7. Cash Dispenser Unit
© 2013
Nautilus Hyosung Inc.
All Rights Reserved.
7-23
Gate Operation Detection Sensor & Encoder Sensor
► CS3
1. Loosen the M3 fixing screw of the CS3 Sensor Bracket (1 place).
2. Disconnect the connector and remove the cable tie to remove the Sensor Bracket.
Be careful not to break the connector pin when removing.
3. Remove the black rubber which attached to back of the Sensor Bracket.
4.
Press the part ‘B’ of the sensor softly as shown in the below figure to remove the
lock and the sensor.
5.
To insert the sensor, insert the part ‘A’ first and press the part ‘B’ to lock.
6. Assemble in the order of 4~1.
7. Before tightening screw of CS3 sensor completely, first release the flanger of the
solenoid and make sure to adjust the detection bracket to the center of the sensor.
After checking that, tighten screw completely.