NAUTIKA BREVA 50 CFM Скачать руководство пользователя страница 9

BATHROOM  FAN  –  BREVA  50 / 70 / 90 / 110  CFM

3

Dimensions

Specifications

MODEL

NO.

AIR

DIRECTION

V

HZ

DUCT

DIAMETER

NOISE

(SONE)

POWER

CONSUMPTION

SPEED

(RPM)

WEIGHT

BREVA 50

50 CFM

120

60

4” (10 cm)

0.5

20 W

990

3,5 lbs (1,6 kg)

BREVA 70

70 CFM

120

60

4” (10 cm)

1.5

24 W

1250

3,5 lbs (1,6 kg)

BREVA 90

90 CFM

120

60

4” (10 cm)

2.5

32 W

1450

3,5 lbs (1,6 kg)

BREVA 110

110 CFM

120

60

4” (10 cm)

3.5

42 W

1670

3,5 lbs (1,6 kg)

• For an average ductwork which is 10’ to 15’ (3 m to 4,6 m) long, 4” (10 cm) in diameter with the assumption of a 8’ (2.4 m) high ceiling.
• 50 CFM = 50 square feet  • 70 CFM = 70 square feet  • 90 CFM = 90 square feet.  • 110 CFM = 110 square feet.
• If the area is larger, you may use a fan providing a greater CFM

Wiring diagram

Motor

Capacitor for

longlife of motor

Automatic terminal switch

to 120V AC 60 Hz

Junction box

to switch

to neutral

to ground

black

white

green

FAN HOUSING

8 1/2"

(216mm)

11 1/2"

(292mm)

9"

(230mm)

4"

(102mm)

4"

(102mm)

4 5/8"

(118mm)

4"

(102mm)

4 5/8"

(118mm)

9"

(230mm)

8 1/2"

(216mm)

11 1/2"

(292mm)

Содержание BREVA 50 CFM

Страница 1: ...s t te plate capuchons de connexion clous ruban conduits tournevis cruciforme et couteau lame r tractable Outils utiles non inclus perceuse lectrique et forets Retirez soigneusement l appareil de la b...

Страница 2: ...s de minuterie Les minuteries m caniques ne sont pas des dispositifs de r glage semi conducteurs 10 Ce ventilateur d a ration est approuv pour une utilisation au dessus d une baignoire ou d une douche...

Страница 3: ...60 4 10 cm 2 5 32 W 1450 3 5lbs 1 6 kg BREVA 110 110 PCM CFM 120 60 4 10 cm 3 5 42 W 1670 3 5lbs 1 6 kg For an average ductwork which is 10 to 15 3 m to 4 6 m long 4 10 cm in diameter with the assump...

Страница 4: ...ort sur la solive pour que le dessous du ventilateur soit effleurement avec le plafond fini Clouer ou visser solidement le support en place Figure 3 ATTENTION POUR UNE INSTALLATION APPROPRI E UTILISEZ...

Страница 5: ...onnecter le fil de mise la terre provenant de la r sidence au fil Vert du r ceptacle du ventilateur Figure 7 Utiliser des m thodes approuv es pour toutes les connexions SECTION 6 Compl tion de l insta...

Страница 6: ...acez la moteur 2 Le ventilateur fonctionne mais l air circule plus lentement que la normale 2 Obstruction dans les conduits d vacuation 2 V rifier pour toute obstruction dans les conduits Les plus cou...

Страница 7: ...long the life of the motor PREPARATION Tools Required for Assembly not included Hammer Drill Bits Flathead Screwdriver Wire Nuts Nails Duct Tape Phillips Screwdriver Utility Knife Helpful Tools not in...

Страница 8: ...s Mechanical timers are not solid state devices 10 This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit Do not use fans over a bathtub or shower...

Страница 9: ...5lbs 1 6 kg For an average ductwork which is 10 to 15 3 m to 4 6 m long 4 10 cm in diameter with the assumption of a 8 2 4 m high ceiling 50 CFM 50 square feet 70 CFM 70 square feet 90 CFM 90 square...

Страница 10: ...g bracket line up the bracket on the joist so the bottom of the fan will be flush with the finished ceiling Nail or screw the bracket in place securely Figure 3 WARNING PROPER INSTALLATION REQUIRES A...

Страница 11: ...e wall switch to the Black wire from the fan s receptacle Connect the ground wire from the house to the Green wire from the fan s receptacle Figure 7 Use approved methods for all connections SECTION 6...

Страница 12: ...r 2 Fan is operating but air moves slower than normal 2 Obstruction in the exhaust ducting 2 Check for any obstructions in the duct ing The most common are bird nests in the roof cap or wall cap where...