background image

14

RECOMMENDED ACCESSORY

Vacuum valve system

remove the plug of M16 accessory 

port from the housing

remove the cap from the vacuum 

valve

slightly lubricate the o-ring and 

make sure the o-ring is in place

then tighten the vacuum valve to 

the housing with the tool provided

connect hand pump to the valve 

and pump several times until it 

reaches the target vacuum level 

close vacuum valve cap

It is recommended to leave the housing 

for at least 20mins to ensure it is sealed. 

If the LED light changes from steady 

green light to rapidly 

fl

 ashing yellow light, 

that means there is a leakage. Please 

check every O-ring and then conduct the 

vacuum test again.

hand pump

moisture alarm 

window

accesory port

on housing

vacuum valve

1

2

Moisture alarm window colour indication :

Steady Blue

Flashing Blue

Steady Green

Steady Red

Flashing Yellow

Flashing Red

Alternating 

Blue and Red

device is turned on
standby mode,

ready for pumpng

target vacuum level

is reached

out of battery

vacuum level

is dropping

vacuum is totally lost,

circuit stalled untill 

device is switched off

vacuum is totally lost,

circuit stalled untill 

device is switched off

* drawings as illustrations only

Содержание NA - Z7II

Страница 1: ...Housing FF MIL Introduction 2 2 3 4 7 8 Package Contents Important Instructions Part Names and Functions Opening the housing Closing the housing 9 14 Preparation for Use Recommended Accessories PN 172...

Страница 2: ...the included items listed below before using this product If some items are missing or damaged contact your local Nauticam dealer After purchase we suggest that you reuse all packaging materials for f...

Страница 3: ...are supervised and or given instruction by a responsible person concerning use of the product to ensure that they can use it safely Do not seal the housing when travelling by air as this may lead to a...

Страница 4: ...nlock button Still Movie button Multi selector Release mode button Zoom in button Delete button button i Menu button Moisture alarm window Zoom out button AE L AF L button 1 2 3 4 5 7 9 11 13 6 8 10 1...

Страница 5: ...ball Z lens release button Optical cable connector M14 Accessory port Port lock safety button F lens release button Mode dial M16 Accessory port Port locking lever Main Switch Main command dial Port...

Страница 6: ...iews Playback lever Fn 2 lever Shutter release lever Movie record lever 1 4 Threaded tripod holes Zoom Focus knob AF ON lever ISO lever Front dial Display lever Zinc Anodes Fn 1 lever 3 7 9 11 1 4 8 1...

Страница 7: ...7 OPENING THE HOUSING depress housing unlock button turn housing lock outward lift up the back housing drawings as illustrations only 1 2 3...

Страница 8: ...nd lubricate the main O ring make sure nothing is caught between front and back housing and that they are fully aligned before locking turn housing lock inward until you hear and feel it click into pl...

Страница 9: ...efore sliding in the camera slide the camera tray back into the housing along the tray rail attach the camera tray by tightening the tray screw into the tripod socket of the camera lock camera tray pl...

Страница 10: ...rt Mounting depress safety button and rotate anti clockwise lubricant the port O ring before mounting align index mark push port assembly straight in rotate locking lever clockwise to lock 1 2 3 drawi...

Страница 11: ...ing an O ring remover clean the O ring groove with a cloth and ensure that it is free from salt or other foreign materials lightly coat it with provided lubricant return the main O ring by slowly pres...

Страница 12: ...switch on the alarm the moisture alarm window will flash in BLUE when it is working correctly test the alarm connect the wires with a dampened cotton bud the alarm will give a repeating beep and the m...

Страница 13: ...on to release pressure before unlocking port lock If using without vacuum valve please follow from step 2 unlock port lock and remove port assembly press the blue button to reset vacuum alarm before r...

Страница 14: ...LED light changes from steady green light to rapidly flashing yellow light that means there is a leakage Please check every O ring and then conduct the vacuum test again hand pump moisture alarm wind...

Страница 15: ...not travel with camera inside housing Operate all controls and buttons at least 3 times while immersed in fresh water We recommand cleaning and inspecting the main O ring each time after diving for an...

Страница 16: ...d service center s Please note that this warranty only applies when the product is pur chased in the territory where the service center is lo cated NAUTICAM accepts no liability for any damage to and...

Страница 17: ...25036 HDMI D C cable in 190mm length Hard Anodized Aluminium Alloy 360 mm 3 10 kg 100 m N 120 Port System Abrasion Resistant Polycarbonate 200 mm 0 07 kg w camera battery 160 mm 1 x M28 1 x M16 1 x M...

Страница 18: ...Nauticam Internationl Ltd Rm 2203 CCT Telecom Bldg 11 Wo Shing St Fo Tan Hong Kong Tel 852 26902711 Fax 852 26909778 URL www nauticam com Gallery www nauticam smugmug com...

Отзывы: