background image

3

IMPORTANT INSTRUCTIONS

Water-tight test of the housing (without 

monitor inside) before usage is recom-

mended as well as any O-ring renewal 

and port change.

Use only Nauticam lubricant on silicone 

rubber O-ring.

Discontinue use immediately when there is 

a sign of leakage.

Do not expose the housing in direct 

sunlight for a prolonged period.

Prevent any sand or dust or water pen-

etration inside the housing. Be extra 

careful when inserting or removing the 

monitor.

This product is not intended for use by 

children, or persons with reduced physical, 

sensory or mental capabilities, or lack of 

experience and knowledge, unless they 

are supervised and/or given instruction by 

a responsible person concerning use of 

the product to ensure that they can use it 

safely.

Do not seal the housing when travelling by 

air as this may lead to a pressure difference 

between the atmosphere and inside the 

housing.

Only the accesories specified by 

Nauticam must be used. Third-party 

accessories may result in malfunctions 

or damage to the product.

Do not stretch any O-rings excessively. 

Only remove it using Nauticam O-ring 

remover.

Do not open the housing in wet or sandy 

environment. Protect the housing from 

moisture and debris in order to prevent 

malfunction or leakage.

1

3

5

7

9

11

12

4

6

8

10

2

Do not attempt to remove parts of the 

housing yourself. Repairs must be done 

at authorized service centers only.

The housing should be positioned on the a 

stable and safe surface on land.

Содержание NA-SHINOBI-H

Страница 1: ...ion 2 2 3 4 7 8 Package Contents Important Instructions Part Names and Functions Opening the Housing Closing the Housing 9 16 11 18 Setup Options Preparation for Use Cable Connection Pre installed M16...

Страница 2: ...length M25 M16 Step Down Adaptor 25625 M16 Vacuum Valve II NAV0014 Mounting Ball with screws Pre installed items SDI Cable 0 75m length M25 M16 Step Down Adaptor 25625 M16 Vacuum Valve II NAV0014 Moun...

Страница 3: ...ervised and or given instruction by a responsible person concerning use of the product to ensure that they can use it safely Do not seal the housing when travelling by air as this may lead to a pressu...

Страница 4: ...tton Luma Waveform button Monitor button Close button Vectorscope zoom button RGB Histogram button Settings lever Vectorscope button Analysis button RGB Parade button Histogram button 1 2 3 4 5 7 9 11...

Страница 5: ...5 PART NAMES AND FUNCTIONS Power button NAV0014 Mounting ball with screws M25 Accessory port HDMI SDI cable Zinc Anodes 1 5 2 3 4 Front Bottom Views 3 2 4 5 1...

Страница 6: ...6 PART NAMES AND FUNCTIONS Top Side Views Housing unlock button M16 Accessory port Moisture alarm window 3 1 2 2 1 3...

Страница 7: ...THE HOUSING 1 2 3 depress housing unlock button turn housing lock latch anti clockwise to open the housing flip open the back housing when lock latch is aligned to open position drawings as illustrat...

Страница 8: ...nothing is caught between front and back housing and that they are fully aligned before locking main O ring insert the housing shaft into the shaft hole and then rotate the lock latch clockwise until...

Страница 9: ...I 1 4 input 25081 M24 M16 Step Down Adapter is needed when accessory port of the housing is M24 25060 SDI Cable in 0 40m length 25036 HDMI D C Cable in 190mm length 25071 HDMI 1 4 A D Cable in 0 75m l...

Страница 10: ...45 0m length 25058 M16 SDI Bulkhead 25060 SDI Cable in 0 40m length 17924 NA Shinobi S Housing for Atomos Shinobi 5 2 4K HDMI Monitor with SDI input M25 M16 Step Down Adapter 25096 SDI Cable in 0 75m...

Страница 11: ...g levers in the direction as shown connect the HDMI cable to the monitor HDMI connector then place the monitor inside the housing secure the monitor by turning the two locking levers towards the monit...

Страница 12: ...ing levers in the direction as shown place the monitor inside the housing then secure the monitor by turning the two locking levers towards the monitor connect the SDI cable to the monitor SDI connect...

Страница 13: ...nto the SDI bulkhead connect the 25060 SDI cable from SDI bulkhead tighten the cable by turning the screw clockwise rotate the cable towards the housing before placing the monitor drawings as illustra...

Страница 14: ...n as shown place the monitor inside the housing then secure the monitor by turning the two locking levers towards the monitor wrap the cable around the battery and connect the cable to the monitor SDI...

Страница 15: ...he caps of HDMI SDI cable and bulkhead M24 M16 adapter if needed connect the bulkhead onto camera housing connect the HDMI SDI cable onto the bulkhead connect the internal cable to the camera connecto...

Страница 16: ...ing an O ring remover clean the O ring groove with a cloth and ensure that it is free from salt or other foreign materials lightly coat it with provided lubricant return the main O ring by slowly pres...

Страница 17: ...ture alarm window will flash in BLUE when it is working correctly test the alarm connect the wires with a dampened cotton bud the alarm will give a repeating beep and the mositure alarm window will fl...

Страница 18: ...ght that means there is a leakage Please check every O ring and then conduct the vacuum test again hand pump moisture alarm window vacuum valve 1 2 Moisture alarm window colour indication Steady Blue...

Страница 19: ...ot travel with monitor inside housing Operate all controls and buttons at least 3 times while immersed in fresh water We recommand cleaning and inspecting the main O ring each time after diving for an...

Страница 20: ...d service center s Please note that this warranty only applies when the product is pur chased in the territory where the service center is lo cated NAUTICAM accepts no liability for any damage to and...

Страница 21: ...for connection from monitor to SDI bulkhead 25060 SDI Cable in 0 30m length for connection from monitor to SDI bulkhead 25062 SDI Surface Monitor Cable in 5m length 25065 SDI Surface Monitor Cable in...

Страница 22: ...90mm length 25046 HDMI D D Cable in 200mm length 25036 and 25046 are both included in NA SHINOBI H package Compatible Camera Compatible Camera D5 A9II R Z50 Nikon Sony Canon Nikon Olympus D500 A7IV 5D...

Страница 23: ...Nauticam Internationl Ltd Rm 2203 CCT Telecom Bldg 11 Wo Shing St Fo Tan Hong Kong Tel 852 26902711 Fax 852 26909778 URL www nauticam com Gallery www nauticam smugmug com...

Отзывы: