After start up: 

 

LED indicator 

Status 

Flashing "Blue" light 

Standby mode. The moisture alarm is active, 
and the system is ready for vacuum indication 
whenever a vacuum is detected. 

Flashing "Red" light 
with beeping sound 

Moisture is detected.  

Flashing "Yellow" light 

Some vacuum is detected, target vacuum level 
is not reached. 

Steady "Green" light 

Target vacuum level is reached. 

Rapidly flash "Yellow" 
light 

Vacuum is dropping. (Will occur only after 
target vacuum level is reached) 

Rapidly flashing "Red" 
light 

Vacuum is totally lost. Circuit stalled until 
switched off. (Will occur only after target 
vacuum level is reached) 

Содержание NA-GX9

Страница 1: ...1...

Страница 2: ...em through the innovative designs of our products We strive to achieve a high level of user friendliness by allowing stress free installation and easy operation of all important functions of the camer...

Страница 3: ...ents 7 Specifications 8 Identification of Parts 9 Opening and Locking the Housing 13 Preparation of the Housing 15 Installing the Camera 19 Mounting the Port 21 Changing the Viewfinder 24 HDMI Cable R...

Страница 4: ...chaser To return your product for service please contact your regional authorized service centre s Please note that this warranty only applies when the product is purchased in the territory where the...

Страница 5: ...t provided by NAUTICAM Discontinue use immediately should you notice any leakage Store the housing in a robust shock proof container during transportation avoid transporting with any equipment such as...

Страница 6: ...e the product in an environment of high humidity Do not leave the housing and the monitor in direct sunlight for prolonged periods Keep out of reach of children failure to do so could result in injury...

Страница 7: ...PACKAGE CONTENTS NA GX9 housing Pair of handle brackets Shutter release extension Spare silicone rubber O ring for housing O ring remover CR2032 battery Lubricant Set of Allen keys Instruction manual...

Страница 8: ...Surface treatment Hard anodised Display window Abrasion resistant polycarbonate Dimensions Width 194mm Height 128mm Depth 100mm Weight Approx 1 16kg Buoyancy Slightly negative Depth rating 100 metres...

Страница 9: ...IDENTIFICATION OF PARTS Threaded holes for handle brackets Flash up off lever Front dial Housing lock Shutter release lever Mode dial Exposure compensation dial On off lever Housing lock safety butto...

Страница 10: ...mount Port alignment index Lens release button Moisture alarm window M10 strobe mounting base M14 accessory port Threaded holes for handle brackets Zoom Focus knob Port release safety button Port loc...

Страница 11: ...utton Movie button Delete Q MENU RETURN Fn2 button button AF AE LOCK button Playback button Rear dial DISP button MENU SET button Rear control wheel control button ISO button WB button Auto Focus Mode...

Страница 12: ...12 Sacrificial zinc anode x2 1 4 20UNC tripod socket x2 The maximum length of screws that can be used with the tripod sockets is 4mm...

Страница 13: ...13 OPENING AND LOCKING THE HOUSING To open the housing 1 Press the housing lock safety button 2 Turn the housing lock anti clockwise for 270 until the lock reaches the Open position as shown...

Страница 14: ...lose the housing while the housing lock is in the Open position 4 Turn the housing lock clockwise for 270 until the lock reaches the lock position as shown Confirm that the white indicator line on the...

Страница 15: ...in the front part of the housing is free from any foreign material the groove can be cleaned with the aid of a microfiber cloth 3 Place the main O ring into the groove first at the corners then the w...

Страница 16: ...es into flashing blue light standby mode 3 Test the alarm by connecting the two wires near the bottom of the housing with a damp cotton bud the alarm should start giving out a repeating beep sound alo...

Страница 17: ...of the operation LED status identification On start up LED indicator Status Flash Blue light once Indicates a 2nd generation PCB Steady Blue light Battery is normal goes into flashing Blue light stan...

Страница 18: ...eeping sound Moisture is detected Flashing Yellow light Some vacuum is detected target vacuum level is not reached Steady Green light Target vacuum level is reached Rapidly flash Yellow light Vacuum i...

Страница 19: ...Disengage the red camera saddle locks by pressing them inwards Remove the camera saddle from the housing by sliding it outwards 2 Tilt the LCD monitor of the camera upwards then attach the saddle to t...

Страница 20: ...20 3 Lift the ON OFF lever and Mode dial upwards 4 Then install the camera by sliding the attached saddle along the rail in the housing until it cannot go in any further...

Страница 21: ...ever downwards ensuring the actuator correctly engages with the ON OFF lever of the camera 4 Gently push the mode dial downwards until it cannot go any further 5 Confirm that all the controls of the h...

Страница 22: ...22...

Страница 23: ...le ports 1 Remove the O ring from the port inspect for any damage and lightly coat it with the provided lubricant before placing it back into its groove 2 Verify that the port opening of the housing i...

Страница 24: ...24 4 Turn the port locking lever to the release position as shown 5 Lift housing cap...

Страница 25: ...into the port opening of the housing until it cannot go in any further 1 8 Lock the port into place by turning the port locking lever to the inward position To ensure that the port is securely mounte...

Страница 26: ...is housing is designed so that it can be removed and re installed by following the simple steps described below To remove the viewfinder 1 Remove the retainer O ring of the viewfinder inside the rear...

Страница 27: ...periphery of the viewfinder body with lubricant 2 Align the viewfinder with the sleeve in the display window 3 Push the viewfinder from the outside of the housing until it cannot go in any further 4 P...

Страница 28: ...a and monitor housing please kindly refer to the monitor housing manual HDMI cable routing Due to the limited space within the housing the HDMI cable should be routed as the photo on the left The cabl...

Страница 29: ...oved from its groove with the O ring remover and inspected for damage Also check that the O ring retains its original circular shape never stretch the O ring excessively or remove it with a sharp obje...

Страница 30: ...30 OPTIONAL ACCESSORIES P N 25624 M14 Vacuum Valve II Pushbutton Release P N 32204 Nauticam 180 straight viewfinder for MIL housings P N 32205 Nauticam 45 viewfinder for MIL housings...

Страница 31: ...31...

Отзывы: